A cobrahead street light is the familiar arm-mounted road luminaire with an extended, often rounded housing. It can use an older discharge lamp or a purpose-built LED assembly. For an LED replacement or a new road, choose the light distribution, mounting connection and service arrangement together; the outline of the housing is only the starting point.
This guide explains how to recognise the main options, where they work well, and how to compare a proposed fitting without getting lost in wattage labels. It also shows what changes when the existing pole is retained, the road borders homes, or the same site includes both traffic lanes and parking areas.

LED street-light housing and optical assembly.

LED road-light optical face — a product example.
Look for a head mounted at the end of a horizontal or curved arm, with its main optical face directed down toward the road. The housing provides room for the light source, optical components and electrical equipment. Many traditional examples have a bowl-shaped lens underneath; modern LED versions may have a flatter optical face and a shallower body.
The name is useful when discussing a familiar road-light form, but it does not identify the supply voltage, road-lighting class, beam pattern or socket size. Two heads that look alike can need different arms and produce very different results on the pavement. In catalogues, “cobra head”, “cobrahead luminaire” and “cobrahead LED street light” may describe the same broad product direction.
The public scope description of ANSI C136.14-2025 associates the term with enclosed, side-mounted roadway and area luminaires and covers both HID and LED sources. Its scope also recognises that non-HID designs can depart from the historical outline. This helps explain the naming; it does not establish that a particular product complies with the standard. [1]
Cobrahead describes the luminaire family; LED describes the light source; road optic, output and controls describe the selected configuration. Keep these decisions separate when comparing proposals.
Before comparing prices or output, establish what is being replaced. A complete LED luminaire, an LED retrofit kit and an older lamp-based fitting leave different equipment in service. They should not appear as equivalent line items without an explanation.

Side-entry LED street-light housings in several sizes.
A complete LED luminaire brings the enclosure, driver, optics and mounting connection together as one offered assembly. This is a practical route for a new installation and for replacement where the old lantern is worn, difficult to seal or unsuitable for continued service. The proposal should identify the exact output and optic option rather than only a series name.
Its main attraction is a defined replacement assembly: the installer can work from one luminaire drawing and wiring arrangement. The trade-off is that keeping the existing pole does not guarantee keeping every other component. The arm interface, control equipment and pole loading still need to suit the replacement.

LED insert plate for a luminaire retrofit.
A retrofit kit replaces selected internal parts while retaining an enclosure. That can be worth investigating when the housing has a particular appearance, the asset owner wants to preserve it, and a compatible kit is available. The retained enclosure becomes part of the technical decision: its internal space, heat path, mounting points, seals and wiring route all matter.
A kit that physically fits is not automatically an approved conversion. Ask which housing it is intended for, what components are removed, how the assembly is secured and what product assessment applies after conversion. Do not transfer the ratings of the loose LED module or driver to the modified fitting. The existing-pole retrofit guide develops the wider replacement decision.

Open road-light enclosure with an internal LED assembly.
Older cobraheads may use high-pressure sodium or another discharge-lamp technology. Their lamp, ballast and optical enclosure form a system. When planning an LED replacement, record the complete existing input power and the condition of the fitting, rather than copying only the wattage printed on the lamp.
The old installation is a useful survey reference, but a new light does not need to imitate every feature of it. A successful replacement may use a different lumen output or optic to meet the same road task. Compare the calculated result on the road, the retained infrastructure and the maintenance implications.
↔ Swipe the table to read every column.
| Supply option | What remains on site | When to investigate it | Main selection question |
|---|---|---|---|
| Complete LED luminaire | Normally the accepted pole and possibly its arm | New roads or whole-lantern replacement | Does the complete option fit and light the layout? |
| Compatible LED retrofit kit | An identified existing enclosure and other accepted parts | A retained housing has a clear reason to stay | Is the specific conversion suitable for that housing? |
| Existing HID fitting | Existing lamp, ballast and housing | Surveying the current asset before a decision | What actually operates now, and what needs replacing? |
A useful product photograph should lead to a useful question. Start at the optical face, move to the arm connection, then look at the electrical and service space. This makes the comparison more concrete than a list of general claims about efficiency and durability.
LED lenses and reflectors direct light toward the intended area. Count and appearance alone do not reveal the beam. Match the optical option to its photometric file.
The enclosure supports the assembly and carries heat away from the LEDs and electronics. Check the permitted operating environment for the selected configuration; external fins alone do not establish thermal performance.
The mounting opening accepts a defined arm or spigot. The insertion depth, clamping position and angle adjustment need to work with the actual arm on site.
The driver supplies the LED assembly. Identify its input range, control arrangement and replacement route, together with access to terminals, seals and any surge device.

Enclosed LED driver — a component example.
Service arrangements vary between luminaire designs. A hinged door may let a technician reach components while the door stays attached. Other fittings need a different opening procedure. Cooper’s published OVF cobrahead, for example, describes hinged, tool-free service access alongside several optical choices. These are features of that product range, not universal features of every cobrahead. [2]
For a fleet of road lights, ask how a failed driver, optical module or seal will be identified later. A clear product code, wiring record and component reference can be more useful to the maintenance team than an unqualified “maintenance-free” claim.
The Jieyao LED street-light catalogue identifies H, J and Y series. Their published product views let a buyer compare the optical face, body and side-entry arrangement before discussing a particular configuration. H, J and Y are catalogue series names, rather than three universal cobrahead types. These modern road-light designs should be evaluated alongside the traditional housing form according to the same road task.

Jieyao H Series LED road light — catalogue product illustration.
The published H image shows an extended, slim optical plate, individual lens positions and a cylindrical side-entry connection. The pivot beside that connection is visible in the catalogue view.
Compare the optical-face dimensions and the room around the rear joint when an existing arm ends close to other equipment. The connection drawing determines the usable insertion and adjustment; the photograph helps identify the questions.

Jieyao J Series LED road light — catalogue product illustration.
The J image shows a broader rear body, an optical panel set within the front frame and a side-entry tube. The fasteners and closure points are visible around the underside.
For a whole-head replacement, look at the body as well as the lit area. Compare the complete envelope with the available arm position and service clearance. A similar-looking optical panel does not establish the same road distribution.

Jieyao Y Series LED road light — catalogue product illustration.
The Y image shows fins around the optical-face perimeter and an adjustable-looking connection at the rear. The rear enclosure is distinct from the lens area.
When reviewing the offered assembly, connect the mounting detail with the thermal and service documentation. Visible fins explain the external form; the exact luminaire and driver ratings establish its operating conditions.
↔ Swipe the table to read every column.
| Series shown | Visible comparison point | Use it to discuss |
|---|---|---|
| H | Slim optical plate and rear mounting joint | Head envelope, arm entry and selected optic |
| J | Broader body with a recessed optical panel | Body clearance, underside access and mounting fit |
| Y | Perimeter finning and rear connection | Housing envelope, mounting detail and operating environment |
Series images are a useful starting point for identification. The quotation should then tie the selected model and revision to a drawing, rated input, delivered lumens, photometric file, driver and enclosure documentation. The public catalogue does not provide a matched, measured performance table for these three pictured configurations, so their efficacy, IP rating, lifetime or mounting diameter are not ranked here. [5]

Road lighting at a junction — an application example.
The lamp needs to place useful light on lanes, junctions and any pedestrian areas included in the brief. More lumens at the luminaire do not necessarily mean a better road result. Some output can fall beyond the target area, while a narrow bright patch can leave the space between poles darker than intended.
Watts (W) describe electrical input. Lumens (lm) describe luminous output. Lux (lx) describe light arriving on a surface. Road designs may also assess pavement luminance in cd/m², which concerns the light reflected toward a viewer. The conversion from lumens to a useful road result depends on geometry and distribution; it is not a single fixed ratio.
TxDOT’s highway illumination guidance explains that road-lighting level and uniformity depend on luminaire output and distribution, mounting positions and height, pavement characteristics, and pole spacing. It also distinguishes illuminance from luminance. Its project requirements belong to that jurisdiction; the underlying distinction is useful when reading a lighting proposal. [3]
A long road, a wide junction and the edge of a car park require different distributions. Labels such as Type II, Type III or Type IV can help organise available roadway optics, but the label does not by itself select a fitting for a road width. Ask for the IES or LDT file matching the proposed optic, output and configuration, then use it in the actual layout.
Compare maintained lighting criteria, including the relevant minimums, uniformity and glare assessment, rather than selecting the highest initial average. A house-side shield may be useful near a sensitive boundary, but its effect should be included in the selected product data and design. For the arrangement of supports, see the four road-lighting layouts guide.
Suppose two proposed fittings are each listed at 100 W. One lists 13,000 lm and the other 15,000 lm: their arithmetic efficacies are 130 and 150 lm/W. That comparison describes output per input watt. It does not tell you which fitting meets the road layout. The second fitting could still put more of its output outside the target area.
Illustrative numbers only; these are not Jieyao product ratings or a measured road-lighting result.
The strongest application for this luminaire family is an arm-mounted roadway position. The same head family can also serve some access roads and perimeter areas, provided the chosen optics suit the task. Start with the surface and activity being lit, rather than assuming every outdoor area needs the same beam.
On a local street, the road may sit close to bedroom windows, gardens and footways. Keep the view from the neighbouring property in the comparison, along with the traffic lanes. Light directed behind the pole, unnecessary upward tilt and a poorly chosen output can all complicate a design that looks adequate in the centre of the road.
Choose the optical option and any shielding around the agreed boundaries. Then consider the operating schedule and colour appearance. DarkSky and the Illuminating Engineering Society’s shared lighting principles favour directing light to the task, limiting excess output, controlling use and choosing warmer light where possible. Apply local road and environmental requirements to the actual project. [4]
A junction introduces turning lanes, crossing points and several viewing directions. A head selected for a straight road section may not suit that widened geometry. Compare the junction and its approaches together so that a bright central patch does not conceal a poor transition into the surrounding road.
Mounting positions may also be constrained by signs, trees, overhead services or existing infrastructure. If pole locations are fixed, the optic and output need to work within those positions. If this is a new road, coordinate the positions and luminaire choice before either is treated as final.
Industrial roads may have large vehicles, loading entrances and maintenance restrictions. Check whether the proposed luminaire and arm sit clear of the operating envelope, and how a technician will reach them without blocking a critical route. Distinguish the traffic road from adjacent loading faces: the latter may need another fixture arrangement or lighting plane.
A cobrahead can be considered where a pole at the edge needs to throw light into a defined paved area. The direction across that area differs from illuminating a long road, so compare area-oriented and roadway optics on the layout. Where the brief calls for several separately aimed beams, an appropriate area luminaire or floodlight arrangement may be a better starting point.
↔ Swipe the table to read every column.
| Location | Main selection priority | Common mistake |
|---|---|---|
| Residential road | Road and footway performance with controlled spill toward homes | Increasing wattage before checking backlight and tilt |
| Main road or junction | Distribution and transitions across the full geometry | Reusing a straight-road optic everywhere |
| Industrial access road | Vehicle clearance, layout and a workable service route | Treating the neighbouring loading area as the same lighting task |
| Parking or perimeter edge | Forward coverage and boundary control | Choosing a road head by appearance alone |

Pole-arm arrangement for road lighting.
Measure the arm’s outside diameter and usable insertion length. A nominal pipe name is not the same as a measured outside diameter. Compare those measurements with the luminaire drawing, including the clamping zone and any stops or adjustment mechanism. A connection that is almost the right size is not a substitute for the specified fit.
Check the installed orientation as well. The optic must face the intended direction, and the cable needs a suitable entry and protection from sharp edges or pinching. An adjustable mounting joint gives a range of positions; it does not mean that every available angle is appropriate for the lighting calculation.
When an existing pole stays, include the proposed head and arm in the retained-asset review. Weight is one input; exposed area, centre of gravity and any added equipment also matter. A lighter LED head is not enough, by itself, to demonstrate that an existing pole arrangement remains suitable. The accepted mounting configuration should be reflected in the equipment schedule and drawing.
For a new installation, coordinate pole height, outreach, setback and luminaire choice together. This prevents a common ordering problem: a correctly manufactured pole arrives, but its arm places the selected head somewhere different from the lighting model.
Decide whether operation comes from a local photocell, a time schedule, a central cabinet or a connected controller. Switching the supply and dimming the driver are different functions. A controller needs the correct electrical interface, and the driver must support the intended control method.
Do not identify a control system from socket appearance alone. Record the receptacle, wiring and protocol required for the supplied option, including what happens when a controller is absent or fails. If the owner plans a later control upgrade, include that future interface in the initial selection. The Zhaga and NEMA controls guide explains the compatibility questions in more detail.
Colour temperature in kelvin describes the apparent colour of the light; it does not measure road brightness. Choose it alongside the site rules, neighbouring environment and any consistency requirement with retained lights. Colour rendering is another property and should be specified separately where the task requires it. Avoid choosing a cooler appearance simply because it seems brighter in a product photograph.
An enclosure IP rating, an impact rating, electrical surge information and a coating description address different issues. Read each against the selected complete product and its installation. A high IP number does not establish surge protection or coating life, and it does not protect a poorly executed field cable connection.
For coastal or industrial locations, discuss the exposure and service conditions rather than relying on a generic “outdoor” label. The luminaire body, fasteners, mounting interface and pole finish may each need attention. Use the IP66 versus IP67 guide when comparing what those water-ingress tests actually address.
Consider a local-road owner replacing ageing cobraheads while keeping the poles. The existing road has several property boundaries and occasional complaints about spill. The useful starting point is an asset and layout survey, not a one-for-one wattage instruction.
For energy comparison, use complete input power and the same operating hours. An illustrative old installation drawing 170 W per fitting and a proposed 100 W fitting, each operating 4,000 hours per year, use 680 and 400 kWh per fitting. The arithmetic difference is 280 kWh, or about 41.2%. This calculation becomes relevant only after the proposed installation satisfies the lighting task; it is not a measured Jieyao saving or a payback claim.
If dimming is added, calculate energy for the time spent in each operating state. Do not apply the full-power difference to hours when either system operates at another level. Electricity tariffs, maintenance and conversion work also need their own assumptions before a cost comparison is meaningful.
Input power does not specify distribution, maintained output or uniformity. Compare the exact proposed optic in the layout.
Measure it. Outside diameter, available insertion and locking details decide the connection.
Ask whether the offer is a complete head or a conversion that retains the existing enclosure and other parts.
Changing tilt changes the distribution relative to the site. Review it in the lighting design, including glare and boundary effects.
Check enclosure, electrical, environmental and structural requirements separately, against the offered assembly.
Include mounting changes, control compatibility, access and replacement parts when comparing options with the same scope.
The LED light engine may be part of a solar system, but the luminaire must match that system’s electrical output and control arrangement. A mains-powered road head cannot simply be connected to a battery. Solar selection also includes the panel, battery, controller and operating schedule; the cobrahead shape does not define any of those.
Only where its specified connection supports that arrangement or a suitable designed adapter is included. Many cobraheads are intended for side-entry arms. Confirm the installation drawing and orientation rather than rotating a fitting to make it appear to fit.
Only use a conversion intended and assessed for the particular arrangement. A change of lamp can affect optical performance, electrical equipment and heat within the enclosure. Compare that route with a compatible retrofit kit and a complete LED replacement before deciding.
Standardising a product family can simplify spares, but road widths, junctions and boundaries may call for different output or optic options. Record those options clearly so that a common-looking housing is not installed with the wrong configuration.
They are different common housing descriptions. Either family may offer several optics and mounting arrangements, so choose by the actual lighting task and connection. For a broader comparison, read the street-light types and applications guide.
Yangzhou Jieyao Lighting Equipment Co., Ltd. (Jieyao Lighting) supplies outdoor lighting and lighting poles. The company profile explains the business behind this guide.
Jieyao Lighting can use the road layout and pole interface as the starting point for an LED street-light discussion. Send a site plan or measured sketch, the intended mounting height and spacing, the supply and control arrangement, and any existing head and arm photographs. Add the applicable lighting criteria and destination requirements so that the proposed configuration can be compared against the right task.
For a new project, continue with the LED street-light product page. For a retained installation, include the existing asset details before asking for an equivalent. This keeps the discussion focused on a usable assembly and the road result, rather than a housing shape or nominal wattage alone.
The printable checklist puts the road inputs, mounting details, exact fixture option and maintenance questions on one printable page.
↓ Download the printable selection checklist · Discuss your street-light project →Terminology and scope. Full paid standard not reviewed; no compliance claim is made.
A manufacturer example of optical options and hinged service access.
Measurement concepts and layout variables; TxDOT-specific project criteria are not presented as universal.
Direction, output, operating time and colour as environmental selection considerations.
Published H/J/Y series names, corresponding product images and configuration scope; reviewed 21 November 2026. These catalogue images are not site photographs or test reports.
References reviewed 21 November 2026. Product and application photographs come from the supplied Jieyao image library and existing public Jieyao pages. Illustrative calculations are identified at their point of use.
Contact Us
Get a custom lighting solution and quotation for your project.
Yangzhou Jieyao Lighting Equipment Co., Ltd. manufactures outdoor lighting and steel poles in Guoji Town Industrial Park, Gaoyou City, Yangzhou, Jiangsu, China. The company reports a 10,000 m² factory site, more than 60 employees including more than 10 technical personnel, and more than 100 production and testing machines. The present company name dates from 2017; Jieyao Poles’ published history traces the team’s manufacturing lineage to 2006. The stated 15 years of experience refers to the team. The company reports exports to more than 60 countries. Do you have any questions or requests?
Email: jay@jieyaolighting.com