Review a 6 m solar landscape lighting package through three interfaces: the lighting layout, the pole and mounted equipment, and the foundation/civil works. A height or an equivalent-watt label does not release the complete installation.
Decorative solar poles combine several duties: supporting lighting and solar equipment, fitting the streetscape and providing access for service. This guide shows how a buyer can connect an actual inspection record to an order-specific drawing and acceptance plan. Keep the luminaire, pole and civil-work responsibilities explicit when comparing a replacement scheme with a new installation.

Decorative solar lighting beside a road — an application example.
Issue the road or pathway plan, pedestrian and vehicle uses, nearby windows, overhead services, existing foundations and access restrictions. Confirm the lighting criteria and operating schedule with the owner. Show the solar module, luminaire, decorative panels, signs and enclosures on one assembly drawing. Decorative elements also occupy space and add load; the shaft height alone cannot describe that assembly.
FHWA’s 2012 lighting handbook treats layout and mounting selection as a calculation-and-refinement task. Use that method with the project’s applicable current criteria. A spacing copied from another road cannot establish the lighting result at this site.

Decorative solar lighting along a bridge — an application example.

Roadside solar lighting at night — an application example.
Jieyao’s archived report AGXB123W00550, issued on 19 December 2023 by Chengdu Product Quality Inspection and Research Institute Co., Ltd., identifies one submitted 6 m pole. The report records inspection on 15 December 2023 and a pass for the tested items against the stated enterprise technical conditions. Its results sheet provides the following measurements.
| Inspected item | Recorded measurement | Use in a purchasing review |
| Pole height | 6,003.5 mm | Compare the specimen record with the ordered shaft and drawing. |
| Wall thickness | 3.52 mm | Trace the inspected item; do not infer the complete stress distribution from one reported result. |
| Top / bottom diameter | 60.20 / 150.1 mm | Check the reported geometry against the selected shaft and mating details. |
| Average zinc coating | 88.9 μm | Compare coating inspection evidence with the specified coating system. |
| Average powder coating | 102 μm | Keep the paint/powder record distinct from the zinc coating. |
| Base-plate length / width / thickness | 260.5 / 260.8 / 14.82 mm | Check plate identity; these dimensions do not specify bolt spacing or foundation capacity. |
These are measurements of the identified specimen, not recommended dimensions for every 6 m solar pole. The sheet does not establish the capacity of a decorative assembly, a panel bracket or its foundation. Coating thickness is not a conversion to outdoor service years. Release the ordered configuration through its own drawing, loading basis and inspection records.

Steel pole fabrication in a workshop — a production-process example.
| Interface | Information to align | Release or acceptance record |
| Lighting and energy | Exact optic, mounting arrangement, actual electrical load and schedule; solar and battery configuration. | Layout calculation plus the selected equipment and operating-profile documents. |
| Pole and attachments | Equipment dimensions, mass, exposed area, positions, decorative features and site wind basis. | Controlled assembly drawing and structural review for the full arrangement. |
| Base and foundation | Pole reactions, plate/anchor interface, local ground information and utility constraints. | Coordinated anchor and foundation design, setting-out and installation records. |
| Delivery and maintenance | Assembly identifiers, finish protection, service access, replaceable parts and responsibilities. | Inspection/packing records, manuals, commissioning checks and a defects/handover record. |
BSI’s published scope for its EN 40 design guidance identifies site wind, terrain, altitude and topography as design inputs. It does not make a bare “wind force level” a complete design basis or prove this assembly compliant. The responsible designer must establish the applicable code and loads for the destination site, including the actual attached equipment.
A solar supply may reduce the need for a grid feeder, but excavation, foundations, traffic management and internal electrical connections remain project scope decisions. State who surveys the site, supplies anchors, designs foundations, installs equipment and performs acceptance. A turnkey label should resolve those responsibilities rather than imply that every project has the same civil works or completion time.
If an offer uses “150W equivalent,” require the actual electrical input and the corresponding luminaire output and photometric file. Do not use the equivalent value to size a battery. Review lighting and energy performance for the agreed night modes; a dimmed night and a full-output night are different services. Annual operation and consecutive-night claims need the equipment, site conditions and acceptance basis stated together.
For the support package, see Jieyao’s steel poles with panel and luminaire brackets. That scope reference includes a separate 8 m drawing and the 6 m sample report; do not combine their dimensions into one assembly. Send the site plan, equipment arrangement and requested supply/civil-work boundaries through the project enquiry page for an identified offer.
It supports the tested dimensions and coating items for the identified specimen. The full lighting, energy, structural and foundation duties need their own applicable evidence.
Height alone is insufficient. Coordinate the actual support reactions, attachment arrangement, anchor interface, ground conditions and governing design requirements.
Switch-on is a functional observation. Complete the agreed layout, settings, installation, measurement and handover checks for the ordered system.
The measurement table transcribes report AGXB123W00550, identification page and results page (physical PDF pages 3–4; report pages 1–2). The interface and release tables are original purchasing analysis. Apply the specimen measurements within their stated report scope.
Jieyao archive: AGXB123W00550, 6 m pole inspection report, issued 19 December 2023; single submitted specimen.
FHWA, Lighting Handbook (August 2012), Chapter 7, Lighting Application: https://highways.dot.gov/safety/other/visibility/fhwa-lighting-handbook-august-2012/7-lighting-application
BSI, Guidance on the use of BS EN 40-3-1 and BS EN 40-3-3, published scope: https://accord-checkout.bsigroup.com/products/guidance-on-the-use-of-bs-en-40-3-1-and-bs-en-40-3-3
Contact Us
Get a custom lighting solution and quotation for your project.
Yangzhou Jieyao Lighting Equipment Co., Ltd. manufactures outdoor lighting and steel poles in Guoji Town Industrial Park, Gaoyou City, Yangzhou, Jiangsu, China. The company reports a 10,000 m² factory site, more than 60 employees including more than 10 technical personnel, and more than 100 production and testing machines. The present company name dates from 2017; Jieyao Poles’ published history traces the team’s manufacturing lineage to 2006. The stated 15 years of experience refers to the team. The company reports exports to more than 60 countries. Do you have any questions or requests?