Four, six and eight poles describe different ways to distribute lighting positions around a sports field. Four poles concentrate the equipment at fewer locations; six or eight distribute it along more positions. The right arrangement depends on the field, mounting height, optics, player sightlines, neighbours and access. Pole count alone cannot establish the lighting level, uniformity or suitability for television.
On this page
A four-pole stadium photograph can look impressive, but it does not tell you whether that arrangement fits another field. The playing area, pole positions, mounting heights, luminaires and aiming work together. Moving one of those elements can change what reaches the surface and what enters a player’s line of sight.
Start with the sport and level of use. A community training pitch, a competition venue and a broadcast stadium can have different lighting criteria. Establish the required calculation planes, uniformity, glare and spill-light limits before comparing the layouts.
Then draw the actual site, including the playing surface, runoff areas, stands, paths, fences and nearby properties. Poles must fit the available space and the site’s safety and access requirements. A neat arrangement on a blank rectangle is only the start of the decision.

Floodlit football field beside homes and access roads — an application example. Photo: Nathan Van Mullem / Pexels.
Our football field lighting standards guide explains illuminance and broadcast criteria. This guide focuses on how different numbers of pole locations organize the lighting equipment around the field.
A four-pole arrangement uses two lighting positions on each side of a rectangular field, often toward its ends. The poles may be outside the corners or along the sides, depending on the design. “Four poles” therefore does not identify one exact set of coordinates.
With fewer positions, more of the field has to be reached from each location. The optical distribution and aiming become especially important when light must travel to the opposite half or toward the centre. Mounting height and setback need to be assessed together with the luminaires rather than selected from pole count.
A practical attraction is the smaller number of support locations to coordinate. That may help where access is available at the ends of the field but restricted along its middle. It does not automatically reduce the complete project cost: a taller or more heavily equipped support can change the structure, foundation, lifting and maintenance package.
Published Signify football-lighting examples include four-pole arrangements with identified field dimensions, fixture models, mounting heights and calculation assumptions. They are examples of designed combinations, not evidence that the same pole count or wattage achieves the result with different products. [1]
Review the centre and far side of the field, the directions in which players look, and light leaving the boundary. Ask for the complete calculation rather than a single average-lux figure. A photograph of a bright patch below a mast does not answer those questions.
Two examples in Signify’s 2019 football lighting guide illustrate why the pole count is only one part of a scheme. Both show a 105m × 70m field and four poles, but use different mounting heights, floodlights and calculation assumptions. The table summarizes those two published Signify examples. [1]
On a small screen, swipe inside the table to read every column.
| Published parameter | Tango LED gen3 example | ClearFlood Large example |
|---|---|---|
| Field size | 105m × 70m | 105m × 70m |
| Poles / mounting height | 4 × 12m | 4 × 18m |
| Floodlights / stated power | 12 × Tango LED gen3, 500W | 16 × ClearFlood Large, 540W |
| System power | 6kW | 8.64kW |
| Published average horizontal illuminance | >60 lx | >75 lx |
| Published minimum / average | >0.5 | >0.5 |
| Maintenance factor used | 0.8 | 0.9 |
| Source scope | Signify / Philips Football Lighting Guide, 2019, p.4 | Signify / Philips Football Lighting Guide, 2019, p.4 |
The first example uses twelve 500W fittings: 12 × 500W = 6kW. The second uses sixteen 540W fittings: 16 × 540W = 8.64kW. These checks confirm the stated connected power; they do not turn watts into lux. Height, optics, aiming and the maintenance factor also belong to the respective calculation.
Use this style of complete information when requesting a proposal. A drawing of four poles should come with the matching equipment and calculation basis so the reported result can be understood.
A typical six-position concept uses three poles along each long side. Adding a middle pair creates more places from which to aim light into the central area. The designer can divide the lighting task among those positions instead of asking the end positions to reach every part of the field.
That extra flexibility comes with a site requirement: the middle locations must actually be available. They may conflict with stands, pedestrian circulation, team facilities, buried services or maintenance access. A layout that cannot be installed safely is not improved by its calculation result.
Six poles should not be described as a fixed competition class. Two six-pole schemes can differ substantially in field size, pole height, luminaire output, beam distributions and aiming. The count describes the support arrangement; the calculation establishes whether the proposed equipment meets the criteria.
For an existing venue, the middle positions may also change how the scheme is wired and maintained. Include cable routes, isolation, foundation locations and access for servicing in the comparison. They are consequences of the layout, not details to add after the poles have been ordered.

Stadium floodlights beside spectator stands — an application example.
An eight-pole side arrangement commonly places four positions along each long side of a rectangular field. It distributes the lighting equipment among more supports and gives the designer more directions from which to address the playing area.
In some designs that distribution can help manage beam paths, shadows or equipment loading at individual positions. It is not a guarantee of better uniformity or lower glare. Poorly chosen optics or aiming can still produce an unsatisfactory result, even with more poles.
More positions mean more foundations and service locations to coordinate. Compare their effect on civil work, cabling, inspections and maintenance routes. Check whether the proposed poles sit outside the required safety zones and leave gates, service roads and spectator routes usable.
An eight-pole arrangement can be worth studying where side positions are available and the project benefits from distributing the equipment. It should compete against other workable layouts on the same criteria, rather than being labelled the automatic professional option.
Use one field outline and one set of lighting requirements for a meaningful comparison. The diagrams below organize the positions conceptually; they do not prescribe offsets, pole heights, foundations or an approved lighting design.
On a small screen, swipe inside the table to read every column.
| Layout concept | What changes | Site question | Design evidence |
|---|---|---|---|
| 4 poles | Fewer lighting positions; longer paths to some areas | Are the proposed end/side positions available? | Photometry, mounting heights, aiming and full field results |
| 6 poles | An additional pair of side positions | Can middle positions fit circulation and stands? | Same calculation basis and a position-by-position fixture schedule |
| 8 poles | More distributed side positions | Can the site support the extra foundations and access? | Check glare, spill and uniformity; count alone is insufficient |
The most useful comparison package shows the pole coordinates, mounting heights, exact luminaire photometry, quantities and aiming for each option. Keep the maintenance factor and calculation grid consistent where the governing requirements permit. Otherwise a difference in the reported result may come from the assumptions rather than the layout.
For the structural comparison, send the actual proposed equipment arrangement to the pole supplier. A mast supporting several floodlights on an offset headframe needs more information than their combined electrical wattage.
Here is a reproducible way to isolate one effect of adding positions. Take a hypothetical rectangular field 105m long and 68m wide. Put equal numbers of poles along the two long sides, with each row 8m outside the field boundary. Place the first and last positions at the two ends and distribute intermediate positions evenly. The 8m offset is an assumption for this comparison, not a recommended installation clearance.
The greatest plan distance to the nearest pole occurs halfway between adjacent positions and halfway across the two rows. With n poles per side, the largest along-field half-gap is 105 ÷ [2 × (n − 1)], while the across-field distance to a row is 68 ÷ 2 + 8 = 42m.
On a small screen, swipe inside the table to read every column.
| Concept | Positions per long side | Largest along-field half-gap | Largest plan distance to nearest pole |
|---|---|---|---|
| 4 poles | 2 | 52.5m | 67.2m |
| 6 poles | 3 | 26.25m | 49.5m |
| 8 poles | 4 | 17.5m | 45.5m |

Teal dots: pole positions. Orange line: distance to a nearest pole from one of the most distant points.
Pole positions
4 total · 2 per side
Field in this model
105 × 68 m
Row offset assumed
8 m outside each long side
Along-field half-gap
52.5 m
Across-field distance
42 m
Largest nearest-pole distance
67.2 m

Teal dots: pole positions. Orange line: distance to a nearest pole from one of the most distant points.
Pole positions
6 total · 3 per side
Field in this model
105 × 68 m
Row offset assumed
8 m outside each long side
Along-field half-gap
26.25 m
Across-field distance
42 m
Largest nearest-pole distance
49.5 m

Teal dots: pole positions. Orange line: distance to a nearest pole from one of the most distant points.
Pole positions
8 total · 4 per side
Field in this model
105 × 68 m
Row offset assumed
8 m outside each long side
Along-field half-gap
17.5 m
Across-field distance
42 m
Largest nearest-pole distance
45.5 m
Original geometric comparison. These diagrams show positions and distances; they do not show beam directions, lux or a recommended clearance.
The numbers show a geometric opportunity: more positions shorten the largest distance to the nearest support in this model. They are distances, not illuminance or predicted uniformity. The lighting design may aim several luminaires across the field rather than lighting every point only from its nearest pole.
Download the assumptions and calculated distances (PDF) to reproduce the comparison. Review pole heights, beams, glare and the actual permitted locations before translating any concept into a project layout.
There is no reliable conversion from “six poles” to a universal number of floodlights per pole. Different optics send light to different parts of the field. Output, aiming, mounting height and the required lighting criteria determine how the fittings work together.
Dividing total lumens by field area gives a rough arithmetic quantity, but it does not account for how much light reaches the intended surface, its distribution, obstructions or the directions important to players and cameras. Use the specified photometric files in the lighting calculation.
The resulting fixture schedule should identify which lights belong at each position and where they are aimed. That schedule can then be coordinated with the headframe, structural loading, electrical supply and service access.

A multi-floodlight headframe viewed from below.
For the physical support arrangement, see Jieyao’s stadium high mast lighting and steel floodlight poles with fixed crossarms. Choose the support around the calculated equipment arrangement and the maintenance plan.
Existing pole positions are a constraint to study, not a guarantee that the replacement lights will work. Record the positions and heights, inspect the supports and foundations, and obtain the structural information needed to assess the proposed luminaires.
Keeping all four existing poles may be practical if the new photometric design and structure review support it. Adding a pair may improve the available aiming options but also creates new foundations, cable routes and access needs. Compare complete alternatives before deciding that either retention or replacement is cheaper.
For a project retaining an existing mast or lowering system, the LED high mast retrofit guide explains the separate compatibility questions.
After installation, confirm the equipment and aiming match the approved arrangement and carry out the specified acceptance measurements. A calculation is a design prediction; the installed result needs its own checks.
Send a dimensioned plan with the sport, playing and runoff areas, stands and neighbouring receptors. Identify available pole zones and any height restrictions. Add the lighting criteria, supply arrangement, maintenance access and whether the poles are new or existing.
Ask for the recommended arrangement and the reasons for it, together with the calculation and equipment schedule. If two layouts are being compared, request the same deliverables for both. This keeps a four-versus-six-versus-eight discussion tied to a decision the project can actually make.
Download the practical checklist
Jieyao Lighting can use that brief to discuss the pole and headframe configuration for the proposed lighting design. The high mast selection guide helps connect the chosen locations with fixed, lowering or other designed maintenance arrangements.
No. More positions create more aiming choices, but the result still depends on the complete scheme and the site constraints. Compare compliant designs and their installation and maintenance requirements.
Yes, a designed four-pole arrangement can be suitable for a particular training requirement. The count itself does not demonstrate the illuminance, uniformity or glare result.
No. They explain the arrangement of positions only. Set-out dimensions, safety clearances, structural supports and buried-service coordination belong to the approved project documents.
[1] Signify / Philips, Lighting Guide: Football, September 2019
https://www.assets.signify.com/is/content/PhilipsLighting/Assets/philips-lighting/new-zeland/20190918-football-recreational-sports.pdf
Manufacturer examples, including four-pole arrangements with product- and calculation-specific conditions; not universal lighting prescriptions.
[2] LED Lighting Supply, Ultimate Guide to Football Field & Stadium Lighting, 29 March 2022
https://www.youtube.com/watch?v=GciwygsLoZI
Manufacturer explanation of four- and six-pole arrangements; product claims and quotations are not transferred to Jieyao.
[3] Jieyao Lighting, Football Field Lighting Standards: Lux, Uniformity and Broadcast
https://www.jieyaolighting.com/news/football-field-lighting-standards-lux-uniformity-and-broadcast
Related guide for criteria and measurement planes; this article adds layout selection rather than repeating standards tables.
Contact Us
Get a custom lighting solution and quotation for your project.
Yangzhou Jieyao Lighting Equipment Co., Ltd. manufactures outdoor lighting and steel poles in Guoji Town Industrial Park, Gaoyou City, Yangzhou, Jiangsu, China. The company reports a 10,000 m² factory site, more than 60 employees including more than 10 technical personnel, and more than 100 production and testing machines. The present company name dates from 2017; Jieyao Poles’ published history traces the team’s manufacturing lineage to 2006. The stated 15 years of experience refers to the team. The company reports exports to more than 60 countries. Do you have any questions or requests?
Email: jay@jieyaolighting.com