What do Type II, III, IV and V mean?
They describe how a luminaire distributes light laterally. Type II has a relatively narrow lateral distribution; Type III reaches farther across the street side; Type IV is used for a stronger forward distribution; Type V is symmetrical around the mounting position. Use the type to shortlist an optic, then test its actual photometric file in the proposed layout. The number does not rank brightness or quality.
On this page
Two LED street lights can look almost identical and illuminate very different parts of a site. The optical lenses, their arrangement and the luminaire’s orientation help determine where the light goes. That makes distribution a useful early selection question when choosing lights for roads, perimeter rows, parking areas or open public spaces.
This guide explains the four commonly requested types, then connects them to roads, perimeter rows and open areas. The small plan-view sketches show the idea of light direction and lateral reach. Their outlines are explanatory, not measured intensity contours or coverage boundaries; use the exact luminaire’s photometric file for the project calculation.
An LED roadway luminaire and its optical array — a product-form example.
Imagine looking down at the site. The luminaire sits at a defined location and orientation. Its distribution describes how luminous intensity is arranged around that position. For a roadside installation, “street side” and “house side” distinguish the forward and rearward sides of the photometric arrangement; those directions must then be mapped to the real site.
A Type II or III label concerns lateral distribution. Another description, such as short, medium or long, concerns longitudinal distribution along the roadway. A catalogue may include both. One classification cannot be used to infer the other. [1]
Type I belongs to the same family of classifications and may appear in catalogues for narrow linear applications. This guide concentrates on Types II through V because they often arise when buyers compare roadway and area-lighting optics. The correct choice still starts with the shape and position of the target area.
Type II — a schematic view of narrower lateral reach.
Roadside lighting along a narrow route — an application example.
Type II is a relatively narrow lateral distribution in this family. It is a candidate where luminaires sit along a route and the area to be lit is mainly beside them, without the same lateral reach required by a wider target. Paths and narrower road arrangements are common reasons to investigate it. The SUDAS classification summary provides a useful introduction to these lateral types. [4]
The useful selection question is whether the actual optic places enough light across the target while avoiding unnecessary spread outside it. A narrow target does not automatically approve every Type II optic: mounting setback, arm overhang and spacing still change the result. Trees, parked vehicles and the route edge can matter as much as the label.
Consider a lighting row along the edge of a service road. The chosen head needs to serve the road surface and any required adjacent task. Review its calculation at the intended mounting position. If the far side is poorly lit, investigate the geometry and other candidate optics rather than assuming that a higher wattage will solve the distribution mismatch.
TxDOT’s Highway Illumination Manual notes that its standard roadway luminaires are typically Type II or Type III. That is evidence of their roadway role in that authority’s practice, not a worldwide instruction to use either type on every road. [2]
Type III — a schematic view of greater street-side reach.
Type III is worth investigating when the target extends farther across the street side than a narrower candidate serves well. From the same row, that reach may help cover a wider road or the inner part of a parking area. The actual road width, setback and neighbouring rows determine whether it is useful in the layout.
In a parking area with poles along an outside row, compare whether the optic reaches the working bays and circulation aisle. A Type III candidate may be worth testing where a narrower distribution leaves the inner part underserved. The same extra reach can be undesirable where it falls beyond a narrow site boundary.
Ask for the exact distribution code on the offer. A manufacturer may provide several Type III options with different longitudinal spread or optical details. Their labels can share the same broad type while producing different layouts. Compare the specific files and proposed fixture orientations, not just “Type III” against “Type III.”
Type IV — a schematic view of forward distribution.
Type IV is associated with farther lateral reach on the street side and is often described as a forward-throw arrangement. It is useful to investigate when a mounting row is at an edge and the target area lies mainly in front: for example, a perimeter row serving an open parking or working area.
This form is useful to compare where poles must remain near a boundary while most of the task lies in front of them. Review the inward reach alongside the views of drivers and neighbours. A layout should show both the useful working area and any sensitive positions around its edge.
A Type IV designation does not establish zero light behind the pole. Rearward light, uplight and high-angle intensity need their own evaluation. Nor does forward throw mean that the luminaire can be aimed upward without consequences. Changing tilt changes where light travels, and the approved layout needs to reflect that mounting angle.
Manufacturer designations also vary. A catalogue may offer a Type IV wide option or use another proprietary code alongside the type. Cooper’s Archeon specification, for example, distinguishes several roadway optical options within one housing family. Use that as a reminder to specify the optic as part of the model identity, not as evidence that all heads of that shape behave alike. [3]
Type V — a schematic view of symmetrical distribution.
Multi-head poles within an open parking area — an application example.
Type V distributes light symmetrically around the luminaire, making it a candidate where the mounting position serves surrounding space rather than principally one side. An open area with a pole inside the target may call for that comparison. The usable result still depends on the exact distribution and the surrounding mounting grid.
Look at what surrounds the pole. In the middle of a reasonably open target, light in several directions may be useful. At a boundary beside homes, some of the same distribution may fall outside the intended area. A central-looking position on a drawing may also be close to an obstacle, so assess the real geometry.
Catalogues may distinguish round-symmetric and square-symmetric distributions. Classification and product codes such as Type V, VS or a manufacturer’s Type 5 designation need to be read with their accompanying photometric description. Do not assume that all “Type 5” products create an identical circular patch on the ground. [1]
For a broad site, a symmetrical candidate is not automatically a high mast system. Mounting height, headframe, maintenance and the number of luminaires are separate system choices. The high mast types and selection guide addresses those support arrangements when the site needs them.
Lateral distribution types: shortlist by geometry · Swipe the table horizontally on a small screen.
| Type | General direction | A layout to investigate | A question the type does not answer |
|---|---|---|---|
| II | Relatively narrow lateral street-side distribution. | A narrower route served from a roadside row. | Will this exact optic meet the target and spacing at the proposed height? |
| III | Greater lateral street-side reach than Type II in the classification. | A road or parking layout requiring more reach from the row. | How do the far edge, overlap and neighbouring property perform? |
| IV | Farther street-side reach; commonly described as forward throw. | An edge or perimeter position directing light into an open area. | What rearward and high-angle light remains at the real orientation? |
| V | Symmetrical distribution around the luminaire. | A mounting position serving surrounding open space. | Is light needed in every direction, and is the actual pattern round or square? |
The applications in this table are starting points for comparison. A road can require a different type at a junction or widening. A parking site can need one optic near the boundary and another farther inside. A single shared housing family may support those different optical choices.
Photometric Toolbox’s published Road Report documentation explains that classification is assessed from an intensity diagram on a grid expressed in multiples of mounting height. For Types II, III and IV, the relevant half-maximum-intensity trace is assessed within the longitudinal distribution range. [1]
Classification boundaries described in the software documentation [1]
| Type | Street-side position of the relevant half-maximum trace |
|---|---|
| II | Beyond 1 mounting height, without extending beyond 1.75 mounting heights. |
| III | Beyond 1.75 mounting heights, without extending beyond 2.75 mounting heights. |
| IV | Beyond 2.75 mounting heights. |
These boundaries are not a road-width or pole-spacing formula
The table describes the classification trace on the intensity diagram. It does not mean that a Type III light uniformly illuminates a road 2.75 times its mounting height, or that a pole spacing can be read from the type number. Ground illumination depends on the complete distribution, output, geometry and contributions from the other lights.
This distinction prevents a common procurement shortcut: converting a type label into a guaranteed coverage rectangle. Use the ratios to understand what the classification describes. Use an actual photometric calculation to evaluate the project.
An optical array helps explain how a compact LED fixture directs light, but its appearance does not provide the complete intensity distribution. Similar-looking lenses can differ in optical design or orientation, and a fixture can use a particular combination of them. The useful evidence is the identified optic and matching photometric file.
When comparing quotations, keep the full luminaire code, optic option, output setting and mounting angle together. If one of those changes, check whether the file and calculation still represent the offered configuration. A generic file for a product family cannot identify every option in that family.
Jieyao’s modular LED street light and high-efficiency LED street light pages are relevant places to begin a model enquiry. Request the available optical options for the exact proposed configuration; the presence of a product page does not establish that every distribution type is available on every model.
Mark the road, path, bays or working area that needs light. Also mark nearby windows, property boundaries, pedestrian viewpoints and other positions sensitive to glare or spill. This makes it possible to judge whether a distribution’s extra reach is useful or unwanted.
Set out candidate pole positions, mounting heights, setbacks, arm overhang and fixture orientation. A convenient existing pole row can constrain the choice differently from a new site. When poles are retained, check the actual arm and luminaire mounting interfaces alongside the optical options.
Shortlist distributions that suit the geometry and calculate them on the same project criteria. Hold the comparison conditions consistent: the relevant output settings, maintenance assumptions, mounting geometry and evaluation area. Changing several assumptions at once can hide the reason a result improved.
Review the criteria required for the application, including the relevant minimums, uniformity and glare assessment. Where required, assess road-surface luminance or other task-specific measures. A higher average illuminance can coexist with dark gaps or excessive light at a boundary.
Use the road-lighting uniformity guide for the calculation review and the light-spill guide for sensitive receptors. Those pages cover the detailed checks; this guide helps choose which optical families to investigate first.
A narrow service road with an existing row. Compare narrower and wider street-side options using the measured setback and arm position. Retain the one that meets the required road criteria without unnecessary reach beyond the target. The lane count by itself cannot choose the type.
A perimeter row around an open parking area. Compare a forward distribution against other suitable optics at the same mounting positions. Check the working bays, the internal aisle and the boundary behind the poles. Consider a different optic for internal rows rather than forcing a perimeter choice across the entire site.
A pole inside a plaza. Investigate a symmetrical option where light is needed around the mounting position. Assess trees, building faces and the edge of the public space; if one side is sensitive, an asymmetric option or a different arrangement may make better use of the light.
The type does not rank brightness. It describes distribution. Compare measured lumen output and the resulting light on the target at the agreed operating setting. Different distributions can make the same lumen output more or less useful for a particular layout.
Recalculate the layout with the proposed replacement. A change in distribution can alter the far edge, overlap, glare and rearward light even when input power is unchanged. Check mounting and orientation as well as the file identity.
The numeral is a classification label, not a lane count. Road width, mounting height, setback, spacing, surface and the authority’s criteria determine whether a specific optic is appropriate.
Send the area plan, target lighting criteria, mounting positions and heights, proposed fixture orientation and any sensitive boundaries. For a retained installation, include the current fixture and arm details. Jieyao’s contact page can be used to coordinate the proposed model and its photometric file against those inputs.
Download the project comparison sheet
Street-light optic comparison — printable PDF
Editable CSV version (ZIP download)
Use one column per candidate and keep the drawing or calculation reference beside each decision.
[1] Lighting Analysts, Photometric Toolbox: IES Road Report Summary
Primary software documentation for lateral and longitudinal classifications and the mounting-height-based boundaries shown above. Classification terminology is distinguished from project compliance.
https://docs.agi32.com/PhotometricToolbox/Content/Road_Report_Tool/road_report_summary.htm
[2] Texas Department of Transportation, Highway Illumination Manual: Light Distribution Patterns
Authority guidance noting typical Type II and III roadway use in TxDOT practice. It is not presented as a universal road-design requirement.
https://www.txdot.gov/manuals/trf/hwi/lighting_equipment/light_sources-i1002196/light_distribution_patterns-i1023727.html
[3] Cooper Lighting Solutions, Streetworks Archeon ARCH-S specification
Manufacturer example of separate optical designations within a luminaire family; document dated March 31, 2026. Its options and performance are not assigned to Jieyao products.
https://www.cooperlighting.com/api/assets/v1/file/CLS/content/671301ebee584c058098ad410072d419/Streetworks-ARCH-S-Spec-Sheet.pdf
[4] Iowa SUDAS Design Manual, Chapter 11: Street Lighting, archived 2021 compilation
Section 11B-1, printed page 4, summarizes lateral distribution types. Referenced for classification background, not as the current authority criteria or legal requirements for a new project.
https://www.intrans.iastate.edu/wp-content/uploads/sites/15/2021/12/Chapter_11-2021.pdf
Contact Us
Get a custom lighting solution and quotation for your project.
Yangzhou Jieyao Lighting Equipment Co., Ltd. manufactures outdoor lighting and steel poles in Guoji Town Industrial Park, Gaoyou City, Yangzhou, Jiangsu, China. The company reports a 10,000 m² factory site, more than 60 employees including more than 10 technical personnel, and more than 100 production and testing machines. The present company name dates from 2017; Jieyao Poles’ published history traces the team’s manufacturing lineage to 2006. The stated 15 years of experience refers to the team. The company reports exports to more than 60 countries. Do you have any questions or requests?