- Product details
-
A pole-only scope for solar street lighting
A solar street light pole supports the equipment package; it does not by itself define the solar system. This page focuses on the steel shaft, PV-panel support, luminaire bracket, enclosure provision, cable routing and foundation interfaces. Panels, batteries, controllers, luminaires and operating autonomy should be specified separately unless the supply schedule explicitly includes them.
Keeping the pole and system scopes distinct helps buyers compare quotations. The pole designer needs the dimensions, mass, center of gravity and projected area of each mounted component. The solar-system designer needs to confirm panel orientation, shading, battery location, cable losses and energy performance. Both teams should approve the same interface drawing before manufacture.

Steel pole fabrication work for a solar lighting support
Solar lighting pole configurations and mounting details
Jieyao’s solar-pole product material covers separate-panel lighting, all-in-one luminaire supports, top or side panel brackets, single or double arms and pole-mounted battery-box supports. This page supplies the steel support and agreed interfaces; energy performance belongs to the selected solar equipment package.
Configuration Product arrangement Detail that defines the assembly Separate-panel layout Independent PV bracket and luminaire arm Panel tilt/azimuth, arm outreach and clearance between both devices. All-in-one luminaire support Top mounting or a short arm for the integrated light Exact luminaire tenon or bracket interface, mass and exposed area. Top or side PV bracket Project-selected bracket position and detachable connections where specified Panel mounting-hole pattern, orientation reference and cable entry. Single or double arm One-sided or two-direction luminaire arrangement Combined panel, luminaire and arm load; a double arm is not automatically symmetrical. Battery-box support Pole-mounted support or an independently located battery arrangement Box dimensions, mass, access, cable route and responsibility for the enclosure. The bracket, anchor cage, assembly-handling and finished-road images show the support at different stages. The structural drawing should locate the panel bracket, luminaire connection, enclosure support and access openings. Panel inclination and bracket outreach change the applied loads; neither can be selected from pole height alone. Match loose brackets and fasteners to the pole identifier in the packing list.
Representative assembly drawing: 8 m pole with PV support
The representative configuration is an 8 m tapered steel pole with a separate solar-panel bracket and luminaire arm, documented in the supplied solar-pole drawing. Unlike the earlier conventional 6 m shaft reference, this drawing includes the panel support, its tilt and hole pattern, the arm, flange and stiffeners on the same sheet. The descriptive height is not an invented stock model code.

Original archived 8 m solar-pole assembly drawing. The source notes that the anchor cage is not included; final equipment and foundation interfaces still require release approval.
Product item Documented configuration Pole shaft 8,000 mm; tapered 60 mm top / 150 mm bottom; 3.5 mm wall; Q235 steel. Finish Hot-dip galvanizing plus painted finish; drawing specifies RAL 9016 matt white. Luminaire arm 48 mm diameter × 1,200 mm length; brace marked 32 mm diameter × 750 mm; 60 mm mounting sleeve. PV support 35° panel inclination indicated; support size note 760 × 800 mm with mounting-hole centres 400 × 730 mm. Bracket interface 6 × M10 connections indicated; sleeve detail marked 76 × 2.0 × 200 mm. Confirm mating fit on the released drawing. Base plate 400 × 400 × 12 mm; 300 × 300 mm hole-centre spacing; 4 slots 28 × 42 mm. Stiffeners 4 plates marked 120 × 180 × 8 mm. Foundation supply boundary Drawing notes anchor cage excluded; base slots do not by themselves identify an anchor-bolt size or foundation capacity. The bracket’s 760 × 800 mm note is a support dimension, not a confirmed PV-module model or electrical rating. The separate panel model, mass, hole pattern and local wind input must match this assembly before fabrication. No structural calculation or bracket-load test has been verified for this configuration.
Separate evidence remains available for a 6 m pole sample under report AGXB123W00550 (issued 19 December 2023): height 6,003.5 mm, wall 3.52 mm, top/bottom diameter 60.20/150.1 mm, average zinc 88.9 μm, powder coating 102 μm and flange 260.5 × 260.8 × 14.82 mm. These are actual reported results for another specimen, not measured results of the 8 m assembly.
Documented steel-pole manufacturing reference
Jieyao’s enterprise standard Q/321084 JYZM002—2023, issued 23 February 2023 and implemented 24 February 2023, records the following manufacturing reference values. These are documented criteria, not measured results for the product shown on this page. The quotation and approved drawing identify the configuration being supplied.
Item Documented reference Application and limit Shaft material Q235 or material with similar properties; material thickness ≥3 mm Clause 4.6; actual grade and thickness stated on the approved drawing. Shaft section Round, hexagonal, octagonal, twelve- or sixteen-sided tapered forms Clause 3.1; selected geometry depends on the product assembly. Pole and arm reference range Straight sections: 3–12 m; cantilevered poles: 5–12 m; arm outreach: 0.75–3 m Table 1 is a general steel-pole range, not a rating for every specialist configuration. Straightness reference Axis straightness error not greater than 0.3% of pole length Clause 4.3.1; dimensional inspection against the applicable drawing. Zinc-coating criterion At least 65 μm for metal thickness below 5 mm; at least 86 μm at 5 mm and above Clause 4.5.2 of this enterprise standard; measured shipment results are separate records. The enterprise standard’s dimensions and coating criteria are steel-pole references. Final panel size, bracket tilt, wind input, anchor design and foundation remain specific to the assembled project; no lighting runtime or backup duration follows from these values.
Panel and luminaire bracket arrangements
A pole may use a dedicated panel bracket with a separate luminaire arm, a combined assembly or a project-specific arrangement. The bracket needs to account for panel tilt and orientation, maintenance access, cable entry, structural loading and clearance from the luminaire. The exact geometry depends on the selected panel and light, site latitude and project wind conditions.
A separately mounted battery or controller enclosure can affect access-door location, internal cable paths and pole loading. Show the enclosure size, door swing, mounting height, cooling or drainage requirements and maintenance clearance on the drawing. If the project uses more than one panel, list the complete array and its orientation rather than relying on a generic image.
StructureConfirm the pole geometry, material and connection shown on the project drawing.EquipmentList each luminaire, camera, panel, charger or accessory that adds load or needs service access.SiteMatch the product to the authority, electrical, civil and installation requirements for its location.Product engineering & procurementPanel bracket geometry and orientation
Provide the panel model, dimensions, mass, quantity, tilt range, azimuth and mounting-hole detail. Mark the orientation using a stated north or road reference so that bracket direction is unambiguous on the fabrication and installation drawings. Check panel-to-luminaire clearance, shading, access for cleaning, cable exit and the ability to maintain both devices after installation.
Where a project uses more than one panel or an unusual bracket, show the complete array rather than relying on a generic illustration. The panel presents a significant exposed surface to wind; its area and position should be included with the pole, arm, luminaire and enclosure in the project-specific structural review. A bracket should not be added to an existing pole without checking the shaft, base and foundation.
Solar pole specification schedule
The following table keeps equipment information tied to the steel pole interfaces. It is a procurement schedule, not a universal specification. The project engineer should provide the design values and confirm the structural calculation, electrical routing and foundation.

Handling steel pole sections during assembly preparation
Interface Data to provide Review before release PV panel bracket Panel dimensions, mass, quantity, tilt and azimuth Wind area, shading, service access and orientation reference Luminaire arm Luminaire dimensions, mass, outreach and aiming Clearance from panel and approved light distribution direction Battery / controller enclosure Enclosure size, mass, door swing and ventilation needs Mounting access, route, separation and service envelope Cable routing Cable type, entry points, bend limits and grounding Protected path, access opening and electrical coordination Pole and base Pole drawing, foundation, anchors and finished level Combined equipment load and project design inputs Supply package Pole only, bracket set or complete lighting system Itemized scope, exclusions, documents and installation party This schedule is for project coordination. Final dimensions, loads, materials, finishes, standards and supply scope must be stated in the approved drawing and quotation for the selected model.
Product engineering & procurementLuminaire, battery and controller interfaces
The pole drawing should locate the luminaire, panel bracket, battery or controller enclosure, access doors and cable entries. For each device, record dimensions, mass, mounting method, door swing, connector position and maintenance space. Confirm cable type, routing, bend limits, grounding and any separation requirements with the electrical designer. If an enclosure is mounted to the shaft, check that it remains accessible and does not conflict with the anchor, access opening or other equipment.
The battery and controller arrangement depends on the selected system and environment. The product page does not assume enclosure size, cooling method, battery chemistry, control settings or runtime. Those values belong to the equipment schedule and destination-market requirements. If the solar equipment is supplied by another party, exchange interface drawings before releasing the pole for production.
Fabrication and quality coordination
The released drawing should locate every bracket, access opening, cable entry and equipment cabinet. Mark orientation from a stated north or road reference so panel direction and luminaire throw are reproducible at installation. Coordinate hole patterns and fasteners with the selected devices, and identify any parts that require separate coating or electrical bonding.
Before shipment, compare the pole and loose brackets against the approved drawing. Confirm the arm direction, panel-support geometry, mounting-hole pattern, access door, cable route, base plate and anchor details. If the solar equipment is shipped separately, label the interfaces and include an assembly schedule. The solar commissioning team should verify wiring polarity and system settings at site.
Input review
Receive the controlled layout, equipment data, project specification and foundation interface.Drawing coordination
Resolve the pole geometry, attachment orientation, cable route, access and supply boundary before release.Production and inspection
Check the supplied pole and accessories against the released drawing and agreed inspection list.Product engineering & procurementManufacturing drawing, assembly and inspection
Before fabrication, release a drawing that shows bracket geometry, panel orientation, luminaire direction, enclosure position, access opening, cable path, base and anchor interface. Identify which components are supplied loose and how they are matched to each pole. If brackets have a separate finish or bonding requirement, show that in the notes and bill of materials. Keep the pole drawing and equipment schedule under revision control so device substitutions are reviewed before production.
Inspection can compare the pole and loose brackets with the approved drawing: arm direction, panel-support geometry, mounting-hole pattern, access door, cable entry, base plate, anchor details and supplied fasteners. If panels or luminaires are shipped separately, label the interfaces and provide the agreed assembly instructions. The commissioning team remains responsible for verifying wiring, polarity and system settings at the site.
Applications and design constraints
Solar street-light poles may be used on rural roads, remote access routes, perimeter roads, car parks and other locations where a stand-alone solar system is specified. Suitability depends on solar resource, shading, operating hours, required light level, backup strategy, maintenance access and the project’s energy design. A pole-mounted panel does not guarantee a given runtime or output.
Wind exposure is a key structural input because the panel presents area above the shaft. The pole, bracket, luminaire, enclosure and foundation should be reviewed as a combined load case. For retrofit work, check the existing structure and foundation before adding a panel bracket or battery cabinet.

Anchor cage and foundation interface for a pole installation
Product engineering & procurementSolar pole RFQ matrix: what to send and what to receive
Use the matrix to define whether the request is for a pole only or a wider equipment package. Provide actual device data and site drawings where available, and mark preliminary values so the structural review can identify open assumptions.
The supplier response should identify included brackets, enclosure supports, hardware and documents, along with the drawing revision and any interface approvals still needed from the energy-system, electrical or civil teams.
Interface Input needed from the project Review before release Panel support Panel model, dimensions, mass, quantity, tilt and orientation Wind area, clearance, shading and access Luminaire arm Luminaire data, mounting and aiming direction Clearance from panel and approved lighting layout Battery / controller Enclosure dimensions, mass and access requirements Mounting position, cable route and service space Pole and foundation Pole geometry, design wind input, anchors and base Combined load review and civil drawing match Electrical route Cables, connectors, grounding and isolation Protected path and commissioning responsibility Supply boundary Pole only, brackets, equipment or complete system Itemized inclusions, exclusions and documents Release check: keep project inputs, supplier response and approval owner on the same controlled drawing and document revision.What to provide when requesting a quotation
Provide the project location, pole spacing or layout, required pole height and arm position, PV panel model and dimensions, tilt range and orientation, luminaire data, battery or controller enclosure, cable and grounding requirements, site design wind input, foundation and anchor drawings, corrosion-protection requirements, quantity, inspection and delivery details.
State whether the supplier is responsible for the pole only, brackets and enclosure supports, or the full solar lighting package. Ask for an interface drawing showing the devices, clearances, cable routing and base connection. This avoids a pole quote that appears complete but omits the brackets or installation hardware needed by the project.
Before order release
Ask the supplier to list inclusions, exclusions, required approvals, open interfaces, supplied documents and the drawing revision. Compare quotations only after these points refer to the same scope.
Product engineering & procurementCoordinate the pole with the solar-energy design
The pole supplier needs the selected panel and luminaire data, but energy sizing belongs to the solar-system design. Provide the expected operating schedule, required lighting duty, local solar-resource basis and battery or controller arrangement to the system designer. That team should confirm the equipment models; the structural team can then use their dimensions, mass and exposed area in the pole review.
Keep the energy calculation, lighting layout and pole drawing linked by revision. A changed panel, tilt, luminaire or enclosure can affect more than one package. If the project is shaded, coastal, high-wind or remote, state the exposure and maintenance constraints early so the relevant specialists can review them.
Product engineering & procurementPacking, assembly and site handover for pole-only supply
When the pole and solar equipment are supplied by different parties, agree how brackets and fasteners will be identified and who checks their fit. The packing list should state which items travel with each pole, which devices are shipped separately and which loose hardware is required for assembly. Protect bracket faces, cable entries and finished surfaces during transport and storage according to the agreed handling instructions.
At the site, compare the delivered assembly with the latest drawing before erection. Confirm the panel direction, luminaire orientation, enclosure position, cable route and foundation interface. Record any difference for approval rather than modifying a bracket in the field. The system installer should complete electrical and solar commissioning under the equipment supplier’s procedure.
Production checks and evidence supplied with the order
Production documentation links the released shaft drawing to bracket geometry, flange/anchor interface, equipment-hole patterns and the bill of materials. Inspection should compare the panel direction and mounting holes with the actual device schedule, then record shaft dimensions, weld appearance, material thickness and coating according to the agreed inspection plan. Battery, controller and panel electrical reports do not establish structural capacity of this pole.
Stage Check described by the manufacturing standard Record to match to the delivery Material receipt Check material certificate and thickness Material identity and thickness record linked to the order. Forming and fit-up Measure section geometry, length and mating interfaces Released drawing and dimensional check sheet. Welding Visual examination; sampled ultrasonic or magnetic-particle examination as specified in the standard Weld inspection scope and applicable examination record; not a claim of 100% NDT. Surface protection Non-destructive zinc-thickness measurement and visual finish inspection Coating readings and inspection locations for the supplied batch. Final release Compare pole, accessories and identification against the agreed scope Factory inspection record, conformity document and packing list as agreed. Clauses 5–6 of Q/321084 JYZM002—2023 describe the measurement and inspection methods and require factory quality inspection before release. A written standard establishes the inspection basis; the order-specific records establish what was actually inspected. Confirm the document list in the contract.
Existing corrosion-test evidence: scope of the tested sample
Jieyao holds report A2220577780101001C, dated 10 February 2023, issued by CTI Engineering Testing Co., Ltd., Anhui Branch, for an 11 m street-light pole. Page 3 records a 1,000-hour neutral salt-spray test under GB/T 2423.17-2008, with no red or white rust reported and a pass against the stated client criterion.
This is evidence for the identified test sample. It is not a test of every configuration on this page, does not certify the attached electrical equipment and cannot be converted into years of outdoor service life. For an order, match the material, coating system, specimen and report scope to the offered product.
Frequently asked questions
Does this product page offer a complete solar street-light system?
The page focuses on the steel pole and mounting interfaces. Panels, luminaires, batteries and controls are included only when they are listed in the project quotation.
Can one pole support both a solar panel and a street light?
It can be configured for both when the pole and brackets are designed for the combined equipment loads and clearances. Confirm the exact devices and drawing.
What panel information is needed for pole design?
Provide dimensions, mass, quantity, mounting orientation, tilt range and projected area, along with the site design wind input.
Where should the battery enclosure be mounted?
The location depends on enclosure size, service access, cable route, exposure and project requirements. Show the proposed position on the approved drawing.
Will the pole guarantee a certain number of backup days?
No. Backup duration depends on the solar system design, site conditions, loads, operating schedule and battery specification. It is not established by the pole alone.
Can I retrofit a panel bracket to an existing street light pole?
Only after reviewing the shaft, foundation, bracket attachment, wind area and equipment loads. Existing capacity should not be assumed.
Project note: product illustrations and application images show configuration or use contexts. They do not identify a named customer installation or establish an approval, certification, load rating or specification. Confirm the selected model, project inputs and applicable documents before order release. -
-