Product answer: Jieyao Lighting's 8m galvanized street light pole is a tapered octagonal steel structure with a project-configured straight single arm for roadway and area-lighting projects. The current product reference lists Q235 steel or a project-specified alternative, a flanged base, hot-dip galvanizing and optional powder coating. Shaft thickness, arm outreach, luminaire connection and anchors are not universal 8m dimensions; they are selected from the approved site and equipment design basis.

An octagonal 8m pole is one configurable roadway-lighting structure, not a standard loading rating.
The buyer should issue a location schedule and the selected luminaire data before a pole drawing is approved. A roadway layout may call for different outreach, optical tilt or fixture position from an industrial access road, even at the same nominal height. The pole height selection guide discusses the lighting-planning decision; this product page addresses the 8m octagonal structure and buying interfaces.
| Item | Jieyao reference | Project decision |
|---|---|---|
| Nominal height and form | 8m tapered octagonal shaft | Road width, location and photometric layout. |
| Steel | Q235 or a project-specified alternative | Design basis and required material documentation. |
| Wall thickness | Project-configured | Wind criteria, arm/luminaire loads and shaft openings. |
| Arm | Straight single-arm reference | Outreach, tilt, spigot and electrical route. |
| Base | Flange and anchor-bolt cage | Reactions, hole pattern and foundation design. |
| Finish | Hot-dip galvanizing; optional powder coat | Exposure, coating specification and color. |
A fixture can fit visually while the spigot, insertion depth, clamp, projected area or cable route is wrong. Provide the luminaire datasheet and any camera, sign or other attachment schedule before fabrication. Compare the proposed arm and fixture position with the lighting model, and keep the approved equipment revision paired with the pole drawing. The arm and luminaire mounting guide sets out the mechanical checks in more detail.

Confirm the actual luminaire mount, bracket position and protected cable path on the approved drawing.
The flanged base, anchor cage and concrete design form one engineered interface. The foundation designer should receive the pole reactions and approved plate/bolt detail; the fabricator should receive the agreed anchor template and orientation. Coordinate the access door with cable entry, terminal space, grounding and safe service access. After fabrication, hot-dip galvanizing protects the steel; optional coating for color or additional exposure requirements needs a defined preparation and acceptance scope. The foundation and anchor-bolt guide and coating inspection guide address those separate decisions.

The base plate, anchor layout and service opening must match the project interfaces.
Use the approved drawing revision to check material, octagonal forming, seam and flange welds, straightness, door and arm position before finish. The inspection plan should define any witness points, records, dimensional acceptance and coating checks the buyer actually requires. Pack the pole, arms, anchors and any loose accessories with clear type and lot marks, then reconcile the packing list against the order. Do not infer that a test or certificate is included without confirming it in the supply contract.
| Gate | Check | Record or output |
|---|---|---|
| Engineering | Height, arm, luminaire, attachments, wind and base interfaces | Approved pole schedule and drawing revision. |
| Fabrication | Material, form, welds, door, flange and arm geometry | Agreed dimensional and weld inspection records. |
| Finish | Galvanizing and any specified coating/repair criteria | Finish inspection record where required. |
| Dispatch | Identification, protection, loose accessories and quantities | Marked bundles, packing list and release evidence. |

Release evidence should connect the finished pole batch to the approved 8m type and packing list.
No. Height changes the optical arrangement and structural demand. Compare the 6m curved-arm pole and the selected 10m product by their approved project configuration, not only by nominal height.
The supply boundary is project-specific. State in the RFQ whether the pole-only, luminaire, arm, anchors, internal terminals, coating and installation are included.
No. The wall and base are configured for the governing site criteria, outreach, fixture and attachments, and approved under the project design process.
Request an 8m pole quotation: Send Jieyao a location schedule, luminaire and accessory data, structural criteria, base/foundation requirements, electrical access detail, finish specification and requested inspection documents. Jieyao can then identify a precise octagonal pole configuration for approval.
Plan a parking lot light pole layout with photometric files, protected pole locations, glare control, structural loads, foundations and maintenance access. Height and spacing are project-specific.
Learn how to choose lighting poles for airports and ports. Understand key selection standards including wind load resistance, corrosion protection, pole height, material choice, and safety requirements for aviation and marine environments.
Compare hot-dip galvanizing, direct-to-steel paint and compatible duplex coatings for street light poles by exposure, detailing, inspection and repair scope.
Compare galvanized steel, aluminum and stainless steel light pole assemblies by structural design, fabrication, corrosion control, finish, handling and inspection evidence. Select materials for the project exposure and approved supply scope.
Compare single arm and double arm street light poles for roads, highways, parking areas, and municipal projects. Learn the differences in lighting coverage, installation cost, application scenarios, and how to choose the right street light pole for long-term project performance.
The best pole for solar street lights depends on wind load, environment, and project scale. Learn when to choose steel, aluminum, or galvanized steel poles for different outdoor lighting applications.
Discover the life expectancy of street light poles based on materials like steel, aluminum, and concrete. Learn how climate, installation quality, and maintenance affect pole lifespan in real outdoor lighting projects.
Learn how to install a solar street light with pole step by step, including foundation construction, pole erection, wiring, and system testing. A practical guide for road lighting, parking lots, and outdoor solar lighting projects.
We primarily use high-strength carbon steel (Q235/Q345/ASTM A36). We also offer premium aluminum alloy and stainless steel poles specifically for coastal regions.
Tapered poles are aesthetic with low wind resistance; cylindrical poles are more cost-effective; polygonal poles (usually 8/12/16 sides) offer the highest structural strength, ideal for high mast lighting.
Our engineers perform mechanical calculations based on your local wind speed data, adjusting wall thickness and base design to ensure the poles can withstand winds up to 160km/h.
It typically ranges from 3mm to 12mm, depending on the pole height, weight of the fixtures, and local wind load requirements.
This is an anti-corrosion process of immersing steel in molten zinc. It provides over 25 years of maintenance-free rust protection in standard outdoor environments.
Yes. We provide complimentary foundation reference drawings, including concrete depth, rebar specs, and bolt positioning data.
We follow AWS welding standards and use Ultrasonic Testing (UT) or Magnetic Particle Testing (MT) to ensure welds are free of pores or cracks.
We hold ISO 9001 (Quality), ISO 14001 (Environmental), and CE certification (EN 40) specifically for the European market.
Yes. We can produce sample poles for craft and color confirmation, though sample shipping costs are typically covered by the client.
Steel poles are lighter, easier to transport and install, have a long lifespan after galvanization, and offer high scrap value, making them more eco-friendly.
Galvanized poles are virtually maintenance-free. We recommend checking anchor bolt tightness and the powder coating surface every 3-5 years.
We provide touch-up paint with each shipment. Simply clean the scratch and apply the paint to restore the appearance.
No. Base plate size and hole spacing are designed based on pole height and stress loads. We provide detailed dimensional drawings for each order.
These are accessories (like anti-climb spikes) installed on the lower section of the pole to prevent unauthorized climbing and enhance security.
Yes. We can flexibly adjust section lengths (e.g., 6m+6m or 5m+7m) based on logistics constraints and on-site installation conditions.
Contact Us
Get a custom lighting solution and quotation for your project.
Outdoor lighting manufacturer in Yangzhou, ChinaAbout Jieyao LightingYangzhou Jieyao Lighting Equipment Co., Ltd. is an outdoor lighting manufacturer focused on solar street light systems and high mas... Do you have any questions or requests?
Email: jay@jieyaolighting.com