Home > Products > Lighting Poles & Accessories

Twin-Wing Landscape Lighting Poles

short introduction:Twin-wing decorative steel pole assembly with a documented 8 m configuration, rectangular-section shaft specification and 340 × 340 × 12 mm flange. Request a current drawing, luminaire selection and itemized supply scope.
  • Product details
  • DECORATIVE STEEL POLE ASSEMBLY

    Twin-Wing Landscape Lighting Poles

    A paired, upward-curving lighting head gives this steel pole a distinctive silhouette for landscape avenues and public-space lighting. The 8 m configuration combines Q235 steel, a rectangular-section shaft specification and a 340 × 340 × 12 mm flange.

    Request the photographed style with the shaft, base and lighting items listed in your quotation.

    Request This Pole Configuration
    Twin-wing steel landscape lighting pole in an outdoor landscaped setting

    Twin-wing landscape lighting pole with curved heads and a decorative crown.

    A twin-wing silhouette for a coordinated streetscape

    This product is intended for buyers who want the photographed twin-wing appearance rather than a general selection of decorative poles. The two lighting heads sit above a central fan-shaped ornament, while the straight shaft carries restrained collars and a square lower cover. Review those visible details together when approving the elevation: changing the head shape, collar position or lower cover changes the appearance of a repeated streetscape.

    The 8 m assembly pairs the steel pole with two 120 W LED light sources. The pole data and electrical package should remain separate in the order so a requested lamp substitution does not silently change the accepted steel assembly.

    Configuration basis: the values below describe one documented configuration. They are not a universal height range, structural rating or promise that a different light head fits the same pole.

    Reference product configuration

    ItemDocumented configurationOrdering detail
    Overall height8 mConfirm measurement datum on the final elevation.
    Steel materialQ235 galvanized steelRetain the grade in the material schedule.
    Main shaftSource notation: 2 × 60 × 120 mmConfirm section arrangement on the fabrication drawing.
    Specified wall thickness2.3 mmConfirm the agreed inspection and acceptance basis.
    Lower base size200 × 200 mmCoordinate the visible base envelope with paving.
    Flange plate340 × 340 × 12 mmAnchor holes and setting dimensions require a matched drawing.
    Corrosion protectionOverall hot-dip galvanizingAgree coating requirements for the destination exposure.
    Surface finishGrinding, polishing and powder coatingApprove color and texture using a physical sample.
    Lighting configuration2 × 120 W LED light sources in the source scheduleConfirm current luminaire model, optics and electrical data separately.

    Configuration source: Jieyao supply contract dated 31 August 2026.

    Rectangular shaft and flanged-base interfaces

    The shaft specification uses rectangular steel sections. The source gives their size and wall thickness but does not provide the complete assembly drawing. The final drawing therefore needs to show how the sections form the shaft, where the top assembly connects, and how the lower cover relates to the flange. These details are particularly useful when matching a new batch to an existing row of poles.

    The 340 mm square flange is a defined interface, but plate width alone is insufficient to set anchors in concrete. Obtain the hole pattern, bolt specification, orientation and cable-entry arrangement before foundation work. The reference contract excludes the embedded anchor assembly, so it must be explicitly included or allocated to another supplier in the new order.

    Specify the lighting head without losing the pole identity

    The curved pair of heads and central ornament are the main visual features. A clear front elevation and the original photograph should accompany the RFQ. Ask the supplier to identify detachable components, transport joints, luminaire fixings and the cable route in the submitted drawings. Confirm the safe service direction of any access opening rather than assuming it from a distant photograph.

    The source schedule records a historical 2 × 120 W lighting arrangement. Confirm the exact luminaires proposed for the new order. Put the current luminaire model, input voltage, color temperature, dimming arrangement, photometric file and enclosure requirements on a separate approval line. Road or path spacing should follow a lighting calculation for that selected head.

    Production checks to agree with the order

    The specified finish requirements include two rough-grinding passes, two fine-grinding passes, polishing and powder coating, alongside overall hot-dip galvanizing; agree the fabrication and coating sequence for the order. Agree the accepted appearance and coating requirements before production. The dark color visible in the photograph is a style reference; a screen image does not establish a RAL code, gloss value or approved color sample.

    CheckWhat to confirmRecord to request
    Steel and dimensionsGrade, shaft sections, wall thickness, height and flange dimensionsMaterial identification and dimensional inspection sheet linked to the order
    Fabrication and fitWeld condition, head symmetry, collars, cover fit and cable pathApproved drawing and workshop inspection photographs
    Galvanizing and finishRequired coating system, inspection locations and approved colorCoating measurements and finish acceptance record
    Electrical packageExact head, driver, wiring and control selectionModel-matched datasheet and agreed test documents
    PackingProtection of curved heads, ornaments, shafts and coated contact pointsComponent packing list and pre-dispatch photographs

    Agree the inspection scope and required records in the current order.

    Quotation scope and project inputs

    The reference package includes the pole assembly and LED light sources. Its exclusions include embedded anchors, internal pole wiring, unloading and installation. A new quotation should list each of these items explicitly, together with packing, freight and required technical documents, so the buyer can compare complete offers.

    Send the required quantity, destination, original style photograph, proposed pole locations, luminaire requirements and finish sample reference. Add the project wind and exposure criteria, foundation interface and any proposed signs or banners. Additional attachments alter the design inputs and should be declared before the fabrication drawing is approved. No wind rating, load capacity or concrete foundation size is assigned by this page.

    For other appearances, see the wider decorative steel pole range. For a different shaft or arm geometry, use the custom pole drawing service rather than treating this photographed configuration as interchangeable.

    Frequently asked questions

    Can I order this appearance with a different luminaire?

    Submit the replacement head’s dimensions, fixing, weight and wind area. Its fit and loading must be reviewed while retaining the approved visual details. The documented 2 × 120 W arrangement does not establish compatibility with every head.

    Does the supply include anchor bolts and internal wiring?

    The reference contract excludes embedded anchors and internal pole wiring. Include them as separate items in the current RFQ if you want Jieyao to price them.

    What finish is specified for this pole?

    The documented configuration uses overall hot-dip galvanizing and a powder-coated finish. Confirm the color, texture and required coating acceptance criteria for the new order.

    Which luminaire documents should accompany the order?

    Ask for the offered luminaire model, input voltage, optic, driver data and model-matched enclosure test documents. Confirm these against the selected lighting package before ordering. The pole assembly and luminaire have separate specifications.

    Request the twin-wing pole package

    Send the style reference, quantity, destination and project design inputs. Ask for a current scope schedule, dimensioned drawing, selected luminaire data and agreed inspection documents for the same configuration.

    Send Your Pole Schedule

FAQ,If you have any other questions, please contact us immediately

Parking Lot Light Pole Height and Layout Guide

Plan a parking lot light pole layout with photometric files, protected pole locations, glare control, structural loads, foundations and maintenance access. Height and spacing are project-specific.

Airport and Port Lighting Pole Selection Standards

Learn how to choose lighting poles for airports and ports. Understand key selection standards including wind load resistance, corrosion protection, pole height, material choice, and safety requirements for aviation and marine environments.

Hot-Dip Galvanized vs Painted Street Light Poles: Finish System Guide

Compare hot-dip galvanizing, direct-to-steel paint and compatible duplex coatings for street light poles by exposure, detailing, inspection and repair scope.

Light Pole Material Comparison: Steel, Aluminum and Stainless Steel

Compare galvanized steel, aluminum and stainless steel light pole assemblies by structural design, fabrication, corrosion control, finish, handling and inspection evidence. Select materials for the project exposure and approved supply scope.

Single Arm vs Double Arm Street Light Pole: How to Choose the Right Option for Your Project

Compare single arm and double arm street light poles for roads, highways, parking areas, and municipal projects. Learn the differences in lighting coverage, installation cost, application scenarios, and how to choose the right street light pole for long-term project performance.

What Is the Best Pole for Solar Street Lights? Materials, Selection Guide and Comparison

The best pole for solar street lights depends on wind load, environment, and project scale. Learn when to choose steel, aluminum, or galvanized steel poles for different outdoor lighting applications.

What Is the Life Expectancy of a Street Light Pole?

Discover the life expectancy of street light poles based on materials like steel, aluminum, and concrete. Learn how climate, installation quality, and maintenance affect pole lifespan in real outdoor lighting projects.

Step-by-Step Installation Guide for Outdoor Lighting Projects

Learn how to install a solar street light with pole step by step, including foundation construction, pole erection, wiring, and system testing. A practical guide for road lighting, parking lots, and outdoor solar lighting projects.

What materials are primarily used for your lighting poles?

Confirm steel grade, pole dimensions and corrosion protection in the approved drawing and quotation. Alternative materials and supporting documents depend on the specific order.

What is the difference between tapered, cylindrical, and polygonal poles?

Taper describes a change in shaft size; cylindrical and polygonal describe geometry. Compare the complete pole design and interfaces for the actual project loads.

How do you ensure the wind resistance and safety of the poles?

Assess pole wind resistance for the actual site, wind definition, equipment layout, connections and foundation. Confirm the documented design and rating conditions.

What is the standard wall thickness for your lighting poles?

Wall thickness is determined with the shaft geometry, material, attached equipment, design loads and connections. Confirm the specified thickness and tolerances in the approved pole drawing and structural design for the quoted configuration.

What is hot-dip galvanization, and what is its lifespan?

Hot-dip galvanizing protects steel with zinc. Protective life depends on coating thickness and exposure; confirm project coating requirements, inspection records and maintenance conditions.

Do I need foundation drawings to install the poles?

Use foundation and anchor drawings approved for the selected pole and site. Coordinate supplier interface details with the project foundation design before construction.

How do you inspect the quality of the welds?

Confirm the weld inspection method, coverage, acceptance criteria and required records against the approved pole drawing and project specification.

What factory certifications do you possess?

Review current factory certificates by holder, site, activity and validity. Check lighting-pole product conformity documents separately against the proposed model and destination requirements.

Do you offer sample poles for testing?

Discuss sample poles for finish or workmanship review. Agree the sample format, testing scope, approval criteria, charges and freight before ordering.

Why should I choose steel poles over wood or concrete?

Compare steel, wood and concrete poles for the same duty using actual weights, installation needs, lifecycle costs and documented environmental assumptions.

Do lighting poles require regular maintenance?

Lighting poles need an inspection plan even when galvanized. Set intervals for the actual exposure and condition, and retain records of defects and approved repairs.

How do I repair minor scratches on the powder coating during transit?

Document transit scratches before repair. Confirm damage scope, coating-compatible materials and an approved repair method; cosmetic paint alone does not establish acceptance.

Is the pole base plate size universal?

Pole base plates are not universal. Match plate dimensions, anchor layout, orientation and the approved foundation design before production or replacement.

What are anti-climb guards?

Anti-climb guards deter unauthorized pole access. Review the site, pole attachment, public access and maintenance arrangements before selecting a guard.

Can the lengths of segmented pole sections be customized?

Section lengths can be reviewed against transport and erection limits. The proposed segmentation must also satisfy the structural design, splice or slip-joint details, required overlap and installation method shown in the approved drawings.

Contact Us

Get a custom lighting solution and quotation for your project.
Jieyao Lighting Yangzhou Jieyao Lighting Equipment Co., Ltd. manufactures outdoor lighting and steel poles in Guoji Town Industrial Park, Gaoyou City, Yangzhou, Jiangsu, China. The company reports a 10,000 m² factory site, more than 60 employees including more than 10 technical personnel, and more than 100 production and testing machines. The present company name dates from 2017; Jieyao Poles’ published history traces the team’s manufacturing lineage to 2006. The stated 15 years of experience refers to the team. The company reports exports to more than 60 countries.

Do you have any questions or requests?

Email: jay@jieyaolighting.com
Tel: +86 13815843784
WhatsApp: +86 13815843784
Contact
Copyright © 2026 Yangzhou Jieyao Lighting Equipment Co., Ltd. All rights reserved
×
Send Your Inquiry Today
We use cookie to improve your online experience. By continuing to browse this website, you agree to our use of cookie.

Cookies

WhatsApp avatar

Click to Chat.

Im online now.

Hey, I'm Xu Jie from Jieyao Lighting. What can I do for you? Welcome to contact me, WhatsApp: +86 13815843784

WhatsApp Us

WhatsApp us