- Product details
-
Steel road sign structures
F-Type Cantilever Road Sign Supports
Support a directional sign above the road from a steel column at one side. Jieyao’s project-configured cantilever assemblies bring the post, paired arms and sign attachment interfaces into one coordinated supply enquiry.
The photograph shows the one-sided F-type form listed in Jieyao’s catalogue as LDJT-23604. Send your sign schedule and road layout to request the column, arm and panel arrangement for your project.
Request a Sign Support QuotationCompany catalogue, printed page 236, reference LDJT-23604. Appearance reference. View the full catalogue page.
When a one-sided cantilever arrangement fits
A cantilever support places the sign over its intended traffic approach while keeping the supporting column on one side of the road. The useful comparison is between the sign’s required position and the space available for a column, rather than between pole heights alone.
For an approach sign extending over the carriageway, define the sign face location, orientation and required clearance on the road layout. For a sign positioned beside the road, a shorter roadside post may be sufficient. A wide sign spanning a larger part of the road can require a different support arrangement; compare that geometry before selecting an F-type structure.
This page covers the cantilever post-and-arm assembly. For the wider range of roadside mounting arrangements, see road sign support poles. Traffic signal heads belong to the traffic signal pole enquiry.
A documented F-type configuration
The table below describes a separate supply configuration recorded in a Jieyao contract dated August 2024. It is not a dimension schedule for the catalogue photograph. Use it as a reference for discussing column sections, paired arms and supply scope; a new order needs its own accepted drawing and design basis.
Part Reference specification Decision for a new order Column 7.65 m high; 273 mm round tube; 10.0 mm wall specified in the drawing reference Confirm the height datum, section and material grade on the current drawing. Paired arms 4.7 m long; two 133 mm round tubes, 8.0 mm wall Coordinate arm length, vertical separation and sign attachment positions. Column base plate 550 × 700 × 30 mm Define anchor holes, orientation and cable entry separately. Sign panel 4.0 × 2.4 m; 3.0 mm 1060 aluminium in the source schedule Confirm whether the sign face, rails and clamps are included in the quotation. Finish Passivation without powder coating recorded for this configuration Specify the complete corrosion-protection system and any colour finish for the new order. These values belong to one configuration. The schedule does not establish a universal wind rating, foundation size or interchangeable anchor pattern.
Resolve the sign, arm and base interfaces together
The sign panel connects to rails or clamps, those attachments transfer load into the arms, and the arms connect to the column. Keep the panel dimensions, attachment positions and arm connection on the same drawing revision. Substituting a larger sign after the steelwork has been approved changes the assembly being assessed.
The base plate is another interface, not a foundation specification. Its outside dimensions do not determine anchor diameter, embedment, bolt-circle geometry or concrete dimensions. The structural designer needs the project loads and ground information; the pole supplier and foundation designer then need matching connection information.
For replacement work, send the existing base and arm details before requesting a matching support. Include measured hole positions and orientation as well as photographs. An existing foundation should not be assumed suitable from the visible plate size.
Define what the quotation includes
Separate the steel support from the sign-face package so the offer is easy to compare. The post, arms, connecting plates and agreed fasteners should be identifiable items. List the sign panels, reflective material, backing rails and clamps if they are part of the same order.
The 2024 reference contract excluded embedded anchors, freight, unloading and installation. Treat those as scope questions for a new quotation. State who supplies the anchor assembly, who designs the foundation and who installs the structure. Where a project specifies a reflective material or local approval, identify the required product and supporting documents before including it in the offer.
Inputs that make the enquiry specific
- Road layout, sign orientation, sign face dimensions and required clearances.
- Requested column location, arm length and any limits on the foundation location.
- Sign, rail and accessory weights, attachment positions and proposed future additions.
- Governing design basis, wind inputs, exposure and any applicable serviceability criteria.
- Quantity, destination, finish requirements and the intended division of supply and installation.
Agree the checks and delivery arrangement
Use the approved drawing revision to check the delivered assembly. The relevant dimensions include post height, arm length, mating connection geometry, base orientation and sign attachment positions. Material identification and the specified finish should be linked to the same order rather than to a general company brochure.
Where the design uses detachable arms, agree the trial-fit and component-marking requirements before dispatch. Identify which post, arm and fastener sets belong together, and confirm how the long components will be protected and packed. Site installation then needs the same orientation marks and the accepted foundation details.
Ask for the inspection records, packing list and drawing revision required by your project. For broader steel-pole fabrication information, the custom steel pole service explains the drawing-led enquiry approach.
Cantilever sign support questions
Can the sign panel and reflective material be supplied with the support?
Include them in the enquiry if required. Specify the face dimensions, backing material, rail and clamp details, reflective material and destination requirements. The steel support and sign package should remain separate lines in the accepted offer.
Can the arms be ordered for an existing column?
Send the original column and connection drawings, attachment schedule and site information first. Matching the visible arm length does not establish compatibility. A replacement arm needs a reviewed connection and loading basis for the existing support.
What is needed to quote a different sign size?
Provide the new panel dimensions, mass, orientation and proposed position, together with project wind and design inputs. Those changes may affect the arms, column, connections and foundation; retain them in one coordinated configuration.
Send the sign schedule and road layout
Include the sign dimensions, proposed support location, arm arrangement, project design basis and supply scope. Jieyao can use that information to review the requested steel support configuration and prepare an itemised quotation.
Discuss Your Cantilever Support -
-

