Home > Products > Lighting Poles & Accessories

F-Type Cantilever Road Sign Supports

short introduction:Review an F-type steel cantilever sign support, its column and arm configuration, sign interfaces and quotation scope for road-sign projects.
  • Product details
  • Steel road sign structures

    F-Type Cantilever Road Sign Supports

    Support a directional sign above the road from a steel column at one side. Jieyao’s project-configured cantilever assemblies bring the post, paired arms and sign attachment interfaces into one coordinated supply enquiry.

    The photograph shows the one-sided F-type form listed in Jieyao’s catalogue as LDJT-23604. Send your sign schedule and road layout to request the column, arm and panel arrangement for your project.

    Request a Sign Support Quotation
    One-sided F-type road sign support with a round column and two horizontal arms, shown in the Jieyao catalogue

    Company catalogue, printed page 236, reference LDJT-23604. Appearance reference. View the full catalogue page.

    When a one-sided cantilever arrangement fits

    A cantilever support places the sign over its intended traffic approach while keeping the supporting column on one side of the road. The useful comparison is between the sign’s required position and the space available for a column, rather than between pole heights alone.

    For an approach sign extending over the carriageway, define the sign face location, orientation and required clearance on the road layout. For a sign positioned beside the road, a shorter roadside post may be sufficient. A wide sign spanning a larger part of the road can require a different support arrangement; compare that geometry before selecting an F-type structure.

    This page covers the cantilever post-and-arm assembly. For the wider range of roadside mounting arrangements, see road sign support poles. Traffic signal heads belong to the traffic signal pole enquiry.

    A documented F-type configuration

    The table below describes a separate supply configuration recorded in a Jieyao contract dated August 2024. It is not a dimension schedule for the catalogue photograph. Use it as a reference for discussing column sections, paired arms and supply scope; a new order needs its own accepted drawing and design basis.

    PartReference specificationDecision for a new order
    Column7.65 m high; 273 mm round tube; 10.0 mm wall specified in the drawing referenceConfirm the height datum, section and material grade on the current drawing.
    Paired arms4.7 m long; two 133 mm round tubes, 8.0 mm wallCoordinate arm length, vertical separation and sign attachment positions.
    Column base plate550 × 700 × 30 mmDefine anchor holes, orientation and cable entry separately.
    Sign panel4.0 × 2.4 m; 3.0 mm 1060 aluminium in the source scheduleConfirm whether the sign face, rails and clamps are included in the quotation.
    FinishPassivation without powder coating recorded for this configurationSpecify the complete corrosion-protection system and any colour finish for the new order.

    These values belong to one configuration. The schedule does not establish a universal wind rating, foundation size or interchangeable anchor pattern.

    Resolve the sign, arm and base interfaces together

    The sign panel connects to rails or clamps, those attachments transfer load into the arms, and the arms connect to the column. Keep the panel dimensions, attachment positions and arm connection on the same drawing revision. Substituting a larger sign after the steelwork has been approved changes the assembly being assessed.

    The base plate is another interface, not a foundation specification. Its outside dimensions do not determine anchor diameter, embedment, bolt-circle geometry or concrete dimensions. The structural designer needs the project loads and ground information; the pole supplier and foundation designer then need matching connection information.

    For replacement work, send the existing base and arm details before requesting a matching support. Include measured hole positions and orientation as well as photographs. An existing foundation should not be assumed suitable from the visible plate size.

    Define what the quotation includes

    Separate the steel support from the sign-face package so the offer is easy to compare. The post, arms, connecting plates and agreed fasteners should be identifiable items. List the sign panels, reflective material, backing rails and clamps if they are part of the same order.

    The 2024 reference contract excluded embedded anchors, freight, unloading and installation. Treat those as scope questions for a new quotation. State who supplies the anchor assembly, who designs the foundation and who installs the structure. Where a project specifies a reflective material or local approval, identify the required product and supporting documents before including it in the offer.

    Inputs that make the enquiry specific

    • Road layout, sign orientation, sign face dimensions and required clearances.
    • Requested column location, arm length and any limits on the foundation location.
    • Sign, rail and accessory weights, attachment positions and proposed future additions.
    • Governing design basis, wind inputs, exposure and any applicable serviceability criteria.
    • Quantity, destination, finish requirements and the intended division of supply and installation.

    Agree the checks and delivery arrangement

    Use the approved drawing revision to check the delivered assembly. The relevant dimensions include post height, arm length, mating connection geometry, base orientation and sign attachment positions. Material identification and the specified finish should be linked to the same order rather than to a general company brochure.

    Where the design uses detachable arms, agree the trial-fit and component-marking requirements before dispatch. Identify which post, arm and fastener sets belong together, and confirm how the long components will be protected and packed. Site installation then needs the same orientation marks and the accepted foundation details.

    Ask for the inspection records, packing list and drawing revision required by your project. For broader steel-pole fabrication information, the custom steel pole service explains the drawing-led enquiry approach.

    Cantilever sign support questions

    Can the sign panel and reflective material be supplied with the support?

    Include them in the enquiry if required. Specify the face dimensions, backing material, rail and clamp details, reflective material and destination requirements. The steel support and sign package should remain separate lines in the accepted offer.

    Can the arms be ordered for an existing column?

    Send the original column and connection drawings, attachment schedule and site information first. Matching the visible arm length does not establish compatibility. A replacement arm needs a reviewed connection and loading basis for the existing support.

    What is needed to quote a different sign size?

    Provide the new panel dimensions, mass, orientation and proposed position, together with project wind and design inputs. Those changes may affect the arms, column, connections and foundation; retain them in one coordinated configuration.

    Send the sign schedule and road layout

    Include the sign dimensions, proposed support location, arm arrangement, project design basis and supply scope. Jieyao can use that information to review the requested steel support configuration and prepare an itemised quotation.

    Discuss Your Cantilever Support

FAQ,If you have any other questions, please contact us immediately

Parking Lot Light Pole Height and Layout Guide

Plan a parking lot light pole layout with photometric files, protected pole locations, glare control, structural loads, foundations and maintenance access. Height and spacing are project-specific.

Airport and Port Lighting Pole Selection Standards

Learn how to choose lighting poles for airports and ports. Understand key selection standards including wind load resistance, corrosion protection, pole height, material choice, and safety requirements for aviation and marine environments.

Hot-Dip Galvanized vs Painted Street Light Poles: Finish System Guide

Compare hot-dip galvanizing, direct-to-steel paint and compatible duplex coatings for street light poles by exposure, detailing, inspection and repair scope.

Light Pole Material Comparison: Steel, Aluminum and Stainless Steel

Compare galvanized steel, aluminum and stainless steel light pole assemblies by structural design, fabrication, corrosion control, finish, handling and inspection evidence. Select materials for the project exposure and approved supply scope.

Single Arm vs Double Arm Street Light Pole: How to Choose the Right Option for Your Project

Compare single arm and double arm street light poles for roads, highways, parking areas, and municipal projects. Learn the differences in lighting coverage, installation cost, application scenarios, and how to choose the right street light pole for long-term project performance.

What Is the Best Pole for Solar Street Lights? Materials, Selection Guide and Comparison

The best pole for solar street lights depends on wind load, environment, and project scale. Learn when to choose steel, aluminum, or galvanized steel poles for different outdoor lighting applications.

What Is the Life Expectancy of a Street Light Pole?

Discover the life expectancy of street light poles based on materials like steel, aluminum, and concrete. Learn how climate, installation quality, and maintenance affect pole lifespan in real outdoor lighting projects.

Step-by-Step Installation Guide for Outdoor Lighting Projects

Learn how to install a solar street light with pole step by step, including foundation construction, pole erection, wiring, and system testing. A practical guide for road lighting, parking lots, and outdoor solar lighting projects.

What materials are primarily used for your lighting poles?

Confirm steel grade, pole dimensions and corrosion protection in the approved drawing and quotation. Alternative materials and supporting documents depend on the specific order.

What is the difference between tapered, cylindrical, and polygonal poles?

Taper describes a change in shaft size; cylindrical and polygonal describe geometry. Compare the complete pole design and interfaces for the actual project loads.

How do you ensure the wind resistance and safety of the poles?

Assess pole wind resistance for the actual site, wind definition, equipment layout, connections and foundation. Confirm the documented design and rating conditions.

What is the standard wall thickness for your lighting poles?

Wall thickness is determined with the shaft geometry, material, attached equipment, design loads and connections. Confirm the specified thickness and tolerances in the approved pole drawing and structural design for the quoted configuration.

What is hot-dip galvanization, and what is its lifespan?

Hot-dip galvanizing protects steel with zinc. Protective life depends on coating thickness and exposure; confirm project coating requirements, inspection records and maintenance conditions.

Do I need foundation drawings to install the poles?

Use foundation and anchor drawings approved for the selected pole and site. Coordinate supplier interface details with the project foundation design before construction.

How do you inspect the quality of the welds?

Confirm the weld inspection method, coverage, acceptance criteria and required records against the approved pole drawing and project specification.

What factory certifications do you possess?

Review current factory certificates by holder, site, activity and validity. Check lighting-pole product conformity documents separately against the proposed model and destination requirements.

Do you offer sample poles for testing?

Discuss sample poles for finish or workmanship review. Agree the sample format, testing scope, approval criteria, charges and freight before ordering.

Why should I choose steel poles over wood or concrete?

Compare steel, wood and concrete poles for the same duty using actual weights, installation needs, lifecycle costs and documented environmental assumptions.

Do lighting poles require regular maintenance?

Lighting poles need an inspection plan even when galvanized. Set intervals for the actual exposure and condition, and retain records of defects and approved repairs.

How do I repair minor scratches on the powder coating during transit?

Document transit scratches before repair. Confirm damage scope, coating-compatible materials and an approved repair method; cosmetic paint alone does not establish acceptance.

Is the pole base plate size universal?

Pole base plates are not universal. Match plate dimensions, anchor layout, orientation and the approved foundation design before production or replacement.

What are anti-climb guards?

Anti-climb guards deter unauthorized pole access. Review the site, pole attachment, public access and maintenance arrangements before selecting a guard.

Can the lengths of segmented pole sections be customized?

Section lengths can be reviewed against transport and erection limits. The proposed segmentation must also satisfy the structural design, splice or slip-joint details, required overlap and installation method shown in the approved drawings.

Contact Us

Get a custom lighting solution and quotation for your project.
Jieyao Lighting Yangzhou Jieyao Lighting Equipment Co., Ltd. manufactures outdoor lighting and steel poles in Guoji Town Industrial Park, Gaoyou City, Yangzhou, Jiangsu, China. The company reports a 10,000 m² factory site, more than 60 employees including more than 10 technical personnel, and more than 100 production and testing machines. The present company name dates from 2017; Jieyao Poles’ published history traces the team’s manufacturing lineage to 2006. The stated 15 years of experience refers to the team. The company reports exports to more than 60 countries.

Do you have any questions or requests?

Email: jay@jieyaolighting.com
Tel: +86 13815843784
WhatsApp: +86 13815843784
Contact
Copyright © 2026 Yangzhou Jieyao Lighting Equipment Co., Ltd. All rights reserved
×
Send Your Inquiry Today
We use cookie to improve your online experience. By continuing to browse this website, you agree to our use of cookie.

Cookies

WhatsApp avatar

Click to Chat.

Im online now.

Hey, I'm Xu Jie from Jieyao Lighting. What can I do for you? Welcome to contact me, WhatsApp: +86 13815843784

WhatsApp Us

WhatsApp us