Home > Products > Lighting Poles & Accessories

5m CCTV Camera Pole with Solar Panel and Equipment Box Supports

short introduction:Drawing-configured 5 m steel camera pole with an 800 mm camera arm, solar-panel support and side equipment-box position. Surveillance and electrical equipment are separately specified.
  • Product details
  • JIEYAO · DRAWING-CONFIGURED CAMERA POLE

    5m CCTV Camera Pole with Solar Panel and Equipment Box Supports

    A five-metre steel support arrangement with a camera arm, solar-panel support and side equipment-box position. Use the documented geometry below to request a coordinated pole-and-bracket package for surveillance equipment.

    This is an archived Jieyao design reference, supported by its drawing and supply record. The current order defines the released steelwork and interfaces. Cameras, solar modules, batteries and controls are included only when named in the quotation.

    Request This 5 m Pole Arrangement
    Five metre CCTV pole drawing with solar-panel support, 800 mm arm and equipment-box position

    5 m reference arrangement: shaft, equipment positions and base plate.

    Main shaft5,000 mm reference height
    Camera arm800 mm reach · 3,000 mm level
    Base plate260 × 260 × 16 mm
    Box outline500 × 400 × 200 mm shown

    CONFIGURATION DETAILS

    A layout with separate camera, panel and box positions

    The reference drawing separates the camera arm, panel support, upper auxiliary bracket and equipment box along the shaft. This allows the mounting interfaces to be discussed independently. It does not prescribe the camera model, communications method or energy performance.

    The 5,000 mm dimension is the main pole height. A terminal element extends another 1,500 mm above it. The camera arm is at the 3,000 mm level, so a five-metre shaft should not be described as a five-metre camera mounting position.

    Camera mounting

    An 800 mm outreach arm is shown with a Ø60 mm end detail. Confirm whether the camera attaches directly or through an adapter, and state the required viewing direction.

    Panel support

    The support is shown at the 4,000 mm level. Provide the actual module geometry, fixing pattern, mass and projected area with the equipment data.

    Equipment box

    A 500 × 400 × 200 mm box outline is shown at the 2,000 mm reference level. Specify its enclosure, attachment and cable paths separately from the components inside it.

    PRODUCT DATA

    Drawing and supply-reference dimensions

    PartReference valueMeaning for the order
    Main pole5,000 mmShaft height; separate from camera level and the terminal above it.
    Shaft diameters100 mm top / 160 mm bottomArchived supply schedule; final drawing confirms the profile.
    Shaft wallAt least 3 mm in the archived scheduleHistorical specification, not a current stock measurement.
    Base plate260 × 260 × 16 mmHole pattern and anchors require their own released detail.
    Camera arm800 mm reach; Ø60 mm endAt the 3,000 mm level shown.
    Panel-support level4,000 mmConfirm module position and orientation.
    Module outline1,480 × 670 mm shownOutline reference, not a current module SKU or tested output.
    Upper auxiliary bracketØ35 mm; 195 mm horizontal and 270 mm vertical detailIdentify the intended equipment before manufacture.
    Upper bracket level4,500 mm shownInclude any fitted item in the complete load schedule.
    Box outline500 × 400 × 200 mmAt the 2,000 mm reference level; no IP rating established.
    Air-terminal extension1,500 mm above the shaftMechanical provision, not lightning-system performance evidence.

    The drawing and supply record establish an archived configuration from 2016. The current order uses an approved drawing and equipment schedule. Original contract pages, commercial terms and customer information are not product downloads.

    Read the installation heights correctly

    Three different height references matter in this layout: the main shaft, the camera arm and the extension above the shaft. Specify the required camera lens position from the monitoring task and confirm its relation to the ground, pole foundation and surrounding structures.

    The drawing places the equipment box below the arm and the panel support above it. Changing those positions affects cable lengths, working access and the distribution of mounted equipment. A change to camera height should therefore appear on the revised assembly drawing, rather than be treated as a site adjustment to the bracket.

    Show the complete outline on the site elevation. Include nearby fences, trees, roof edges, overhead services and the intended access route for installation. Identify the foundation level used for the pole dimensions.

    Define the pole package separately from electrical equipment

    Specify the shaft, plate, access cover, arm, panel-support steelwork, box supports and named fasteners. List any enclosure, terminal hardware or anchor set separately so the quotation identifies the complete scope.

    ItemPole-and-bracket quotationSystem interface
    Shaft and armsGeometry and steel connectionsCamera positions and equipment layout.
    Panel supportBrackets and specified fastenersModules, orientation, weight and projected area.
    Box mountingSupport and enclosure if includedInternal components, cables, heat management and protection.
    Camera/networkingMounting provisions unless equipment is listedDevices, field of view, network and commissioning.
    Battery/controllerLocations and supports if specifiedElectrical sizing and documented performance.
    Base/anchorsNamed hardware and interface drawingFoundation design and civil installation.

    The 150 W labels on the archived module outlines are design labels. They are not measured outputs and do not establish energy yield, operating duration or nights of autonomy. This page defines the steel support configuration.

    Match the steelwork to the actual equipment

    Equipment geometry

    Provide camera and module drawings, fixing points, weights and projected areas. Include cabinets, antennas and additional devices instead of leaving them as unspecified allowances.

    Site design basis

    State location, exposure and governing project requirements. The foundation designer needs the accepted pole reactions and actual connection details.

    Maintenance method

    Show how cameras, modules and boxes can be reached and removed. This drawing is a fixed-pole arrangement; it does not establish a ground-level lowering mechanism.

    A module with the same wattage can have a different size or fixing pattern. A replacement camera can change bracket clearance and mounting weight. Keep the accepted equipment schedule tied to the fabrication drawing so those differences are reviewed before production.

    MANUFACTURING DETAIL

    Steel fabrication and connection inspection

    Close view of a circumferential weld on a steel pole component

    Steel weld detail.

    The drawing should identify shaft sections, arm attachments, support positions, access opening and base connection. Inspection compares the manufactured parts with that drawing and the agreed material and finish criteria.

    A weld photograph shows a fabrication detail; it does not establish a weld classification or NDT result. Specify the required method, coverage and acceptance basis for the order.

    During fit-up, review arm direction, bracket positions, box access and cable entries. Identify loose components by pole mark and provide the agreed assembly information with them.

    Pole sections, finish and delivery

    The reference photograph shows pole sections with flanges and access openings during fabrication. It illustrates steelwork requiring dimensional and finish inspection, without identifying the pictured parts as this archived five-metre design.

    The archived order describes galvanizing followed by passivation. Specify the current protective system, appearance, acceptance criteria and any colour requirement in the quotation. A finish statement from another product is not a measured result for this configuration.

    Protect interfaces during packing and keep arms, support parts and fixing sets identifiable. Include the drawing revision, packing list and agreed inspection records with delivery.

    Steel pole shafts with flanges and access openings in a workshop

    Pole sections before finishing.

    Base plate and civil-work interface

    The reference plate measures 260 × 260 × 16 mm. Those three dimensions do not define an anchor pattern, bolt capacity or foundation size. Request the released plate-hole layout and anchor detail for the selected pole assembly.

    The pole supplier and civil designer should agree responsibility for reactions, anchors, template, fixing projection, conduits and earthing. Where anchors are supplied with the steelwork, list their dimensions, materials, nuts and washers in the package. Where anchors are supplied locally, issue the accepted interface drawing before construction.

    Application context: outdoor camera positions

    A yard, access route or perimeter installation needs a clear camera view and a practical service position. The layout determines camera direction and mounting level while preserving access to the cabinet and cable entries.

    Use the dimensioned reference above for the five-metre product enquiry. Send a site plan and device schedule when requesting a variation.

    For other arrangements, compare the CCTV camera pole family. A solar street-light pole carrying a luminaire has a different equipment layout.

    Enquiry checklist

    Reference and quantity

    Identify this five-metre arrangement, quantity and destination. Mark changes to height, reach, bracket levels or box dimensions.

    Equipment and scope

    Send camera, module, enclosure and auxiliary-device drawings. State which equipment and fasteners each party supplies.

    Design and records

    Provide site criteria, supporting-structure information, finish requirements and inspection documents. Identify any witnessing scope.

    Enquire About the 5 m CCTV Pole

    5 m CCTV pole questions

    Is the camera mounted at five metres?

    The main shaft is five metres; the camera arm is shown at the three-metre level. State the required camera position if it differs.

    Does five metres include the upper terminal?

    The drawing shows a separate 1,500 mm extension above the shaft. Confirm the final overall clearance and terminal arrangement.

    Is a complete solar CCTV system included?

    The page defines steelwork and mounting interfaces. Cameras, modules, batteries, controllers and networking are included only when named in the quotation.

    Can the equipment-box size change?

    Provide its outline, mounting, weight and cable entries. Review the support and complete assembly for the changed enclosure.

    Are module power labels performance guarantees?

    No. They are archived design labels. Energy performance requires the selected electrical components and a site calculation.

    Is this a folding or tilting pole?

    The reference is fixed. A lowering arrangement requires a separate coordinated design and operating method.

FAQ,If you have any other questions, please contact us immediately

Parking Lot Light Pole Height and Layout Guide

Plan a parking lot light pole layout with photometric files, protected pole locations, glare control, structural loads, foundations and maintenance access. Height and spacing are project-specific.

Airport and Port Lighting Pole Selection Standards

Learn how to choose lighting poles for airports and ports. Understand key selection standards including wind load resistance, corrosion protection, pole height, material choice, and safety requirements for aviation and marine environments.

Hot-Dip Galvanized vs Painted Street Light Poles: Finish System Guide

Compare hot-dip galvanizing, direct-to-steel paint and compatible duplex coatings for street light poles by exposure, detailing, inspection and repair scope.

Light Pole Material Comparison: Steel, Aluminum and Stainless Steel

Compare galvanized steel, aluminum and stainless steel light pole assemblies by structural design, fabrication, corrosion control, finish, handling and inspection evidence. Select materials for the project exposure and approved supply scope.

Single Arm vs Double Arm Street Light Pole: How to Choose the Right Option for Your Project

Compare single arm and double arm street light poles for roads, highways, parking areas, and municipal projects. Learn the differences in lighting coverage, installation cost, application scenarios, and how to choose the right street light pole for long-term project performance.

What Is the Best Pole for Solar Street Lights? Materials, Selection Guide and Comparison

The best pole for solar street lights depends on wind load, environment, and project scale. Learn when to choose steel, aluminum, or galvanized steel poles for different outdoor lighting applications.

What Is the Life Expectancy of a Street Light Pole?

Discover the life expectancy of street light poles based on materials like steel, aluminum, and concrete. Learn how climate, installation quality, and maintenance affect pole lifespan in real outdoor lighting projects.

Step-by-Step Installation Guide for Outdoor Lighting Projects

Learn how to install a solar street light with pole step by step, including foundation construction, pole erection, wiring, and system testing. A practical guide for road lighting, parking lots, and outdoor solar lighting projects.

What materials are primarily used for your lighting poles?

Confirm steel grade, pole dimensions and corrosion protection in the approved drawing and quotation. Alternative materials and supporting documents depend on the specific order.

What is the difference between tapered, cylindrical, and polygonal poles?

Taper describes a change in shaft size; cylindrical and polygonal describe geometry. Compare the complete pole design and interfaces for the actual project loads.

How do you ensure the wind resistance and safety of the poles?

Assess pole wind resistance for the actual site, wind definition, equipment layout, connections and foundation. Confirm the documented design and rating conditions.

What is the standard wall thickness for your lighting poles?

Wall thickness is determined with the shaft geometry, material, attached equipment, design loads and connections. Confirm the specified thickness and tolerances in the approved pole drawing and structural design for the quoted configuration.

What is hot-dip galvanization, and what is its lifespan?

Hot-dip galvanizing protects steel with zinc. Protective life depends on coating thickness and exposure; confirm project coating requirements, inspection records and maintenance conditions.

Do I need foundation drawings to install the poles?

Use foundation and anchor drawings approved for the selected pole and site. Coordinate supplier interface details with the project foundation design before construction.

How do you inspect the quality of the welds?

Confirm the weld inspection method, coverage, acceptance criteria and required records against the approved pole drawing and project specification.

What factory certifications do you possess?

Review current factory certificates by holder, site, activity and validity. Check lighting-pole product conformity documents separately against the proposed model and destination requirements.

Do you offer sample poles for testing?

Discuss sample poles for finish or workmanship review. Agree the sample format, testing scope, approval criteria, charges and freight before ordering.

Why should I choose steel poles over wood or concrete?

Compare steel, wood and concrete poles for the same duty using actual weights, installation needs, lifecycle costs and documented environmental assumptions.

Do lighting poles require regular maintenance?

Lighting poles need an inspection plan even when galvanized. Set intervals for the actual exposure and condition, and retain records of defects and approved repairs.

How do I repair minor scratches on the powder coating during transit?

Document transit scratches before repair. Confirm damage scope, coating-compatible materials and an approved repair method; cosmetic paint alone does not establish acceptance.

Is the pole base plate size universal?

Pole base plates are not universal. Match plate dimensions, anchor layout, orientation and the approved foundation design before production or replacement.

What are anti-climb guards?

Anti-climb guards deter unauthorized pole access. Review the site, pole attachment, public access and maintenance arrangements before selecting a guard.

Can the lengths of segmented pole sections be customized?

Section lengths can be reviewed against transport and erection limits. The proposed segmentation must also satisfy the structural design, splice or slip-joint details, required overlap and installation method shown in the approved drawings.

Contact Us

Get a custom lighting solution and quotation for your project.
Jieyao Lighting Yangzhou Jieyao Lighting Equipment Co., Ltd. manufactures outdoor lighting and steel poles in Guoji Town Industrial Park, Gaoyou City, Yangzhou, Jiangsu, China. The company reports a 10,000 m² factory site, more than 60 employees including more than 10 technical personnel, and more than 100 production and testing machines. The present company name dates from 2017; Jieyao Poles’ published history traces the team’s manufacturing lineage to 2006. The stated 15 years of experience refers to the team. The company reports exports to more than 60 countries.

Do you have any questions or requests?

Email: jay@jieyaolighting.com
Tel: +86 13815843784
WhatsApp: +86 13815843784
Contact
Copyright © 2026 Yangzhou Jieyao Lighting Equipment Co., Ltd. All rights reserved
×
Send Your Inquiry Today
We use cookie to improve your online experience. By continuing to browse this website, you agree to our use of cookie.

Cookies

WhatsApp avatar

Click to Chat.

Im online now.

Hey, I'm Xu Jie from Jieyao Lighting. What can I do for you? Welcome to contact me, WhatsApp: +86 13815843784

WhatsApp Us

WhatsApp us